Requires 46mm between the floor base and the top of the tile... how many floors are going to have this?
@eltonnoway7864
Жыл бұрын
46mm is the height of the rough in valve assembly. While some rough in valves are mounted on the "surface" of the floor and and covered with the escutcheon cover, this particular design requires the valve to in installed "below" floor level. The cautionary tip is to calculate the total thickness of any subfloor substrate, any waterproofing membranes, floor heating etc and the floor tiles of choice into consideration when creating the necessary "recessed hole" or depth of any mounting platform, so when the valve is installed, the top of the valve assembly will be flush with the top surface of the "finished" floor