AA. Is inverter ka heat exhuast kis side par heat nikalta hai? Up and down ya all four sides?
@usamajafri5794
6 ай бұрын
In day time Jb grid available na ho (load shedding ho) to kia smart load work nahi kerta ?
@zeeshanzaman1598
6 ай бұрын
Sir i have this 12kw latest Nitrox, i already applied for net metering, which option should i use so during load shedding, There should be no export to grid but all of my smart and normal load should work. Means a trube hybrid environment as in villages , there can be 6 yo 8 hours of load shedding during day time. I am using 4X 140amp acid batteries as well. Thank you😊
@alimushaf
Жыл бұрын
Salam. I did the same configurations as you showed. After that, it has been showing 0 consumption and very low numbers. Even though we switched on Water pump, Iron etc.
@engineerarz786
Жыл бұрын
Zero export to ct ma main function kya ha.. Or manual ma home load se kya muraad ha
@TriX1614
2 ай бұрын
I want to use smart load even at night, when the sun is out, how do i do it?
@AdilQayyumOfficial
2 жыл бұрын
Hi, great video for settings. One question, I have same inverter but the installer has set the Work Mode to Zero Export to Load. Smart Load pe ACs hain, wo chalao tou tb b solar k load pe chal jatey hain. What's the different between Zero Export to Load and Zero Export to CT, agr dono pe Smart load chal rha hai.
@EnonTraders
2 жыл бұрын
The inverter in video is with the latest firmware and also the manufacturer mentioned to use zero export to CT particularly for this version of 12 kw inverter. We've also installed several other Inverters where we used zero export to load for smart load operation as well. Zero Export to Load defines as that there will be no export of units be made reference to the load point. So that production will vary as load varies. Zero export to CT means that beyond that CT point export will not be made. Hence in the new 12 kw firmware they've put heavy load/smart load port before the CT Relay connection.
@AdilQayyumOfficial
2 жыл бұрын
@@EnonTraders Thanks for the detailed answer, much appreciated. So generally if I have CTs installed, should I use Zero Export to CT instead of Zero Export to Load?! As load tou sara din vary krta rehta hai, and currently net metering is not enabled, tou which option is correct one for running both smart and critical load?!
@EnonTraders
2 жыл бұрын
It depends of firmware. If its a single phase Inverter then you can use any of the two options but if you've Inverters in parallel or 3 Phase Inverters then I will prefer zero export to CT.
@AdilQayyumOfficial
2 жыл бұрын
@@EnonTraders Alright thanks. It's 3Phase, 12KW Inverex Inverter, latest model. Currently it's working on Zero Export to Load, with smart load. I will try Zero Export to CT and see the difference. 👍
@Munibhusain
Жыл бұрын
A.a can we connect generator on grid port. As i am using the gen port for smart load.
@muhammadammarhussain7761
Жыл бұрын
Sir mera inveter pehla din main wapda jana pa Ac chalta tha per ab nae chala rha please guide
@sairbaloch6294
Жыл бұрын
Bhai f18 error ka kya haal hai
@faizanmahar2513
3 ай бұрын
sir i am using 12kw nitrox 5G hybrid new model. i am using both normal load nd smart load with No battery. inverter working is best in day time complete load uses solar production. But the issue is that in the evening when solad dc voltages becomes Zero the inverter turned OFF and the complete load turned shutdown. nd then in the morning inverter turned ON automatically when detects sunlight. Setting is Zero export to Load. Kindly guide me
@EnonTraders
3 ай бұрын
You should not use smart load without batteries. Without batteries inverter actually do not have anything to invert so you see at night time there is "OFF" written in the middle of the flow so it can't drive load. You should put all the load on the main port and uncheck smart load settings in Gen. Port use window.
@engrdada8162
2 жыл бұрын
A.o.A bhi 6kw NITROX Inverex smart load Genertor port pa cannect kare?
@EnonTraders
2 жыл бұрын
Yes
@tahirarslan2825
2 жыл бұрын
Salam, how much load we can connect on smart load, 12 KW inverex nitrox ?
@EnonTraders
2 жыл бұрын
Maximum 13 KW
@tahirarslan2825
2 жыл бұрын
@@EnonTraders if we are using normal load and smart load(heavy load) together, how much load we can put on each phase lines to be in safe zone. 12KW is 3P . Some told me if we use both normal and smart load, we can not put more than 2 KW on in single phase line, is it true ?
@EnonTraders
2 жыл бұрын
4 kw load on each phase
@rajafraz1003
Жыл бұрын
Sir, i have fronus Matrix 6k with 4 batteries 230ah and 12 solar panels 545 watts Please tell me the batteries setting for My system
Пікірлер: 28