I love this video. Nice work. So simple and straight forward.
@MajewskiPlumbing
4 жыл бұрын
We love these!
@rogerhodges9721
4 жыл бұрын
Note to Navien: At 6 min plus on the video, the speaker advises that the air intake filter should be checked regularly. The part is secured with a screw! For a part that should be checked frequently. even annually, this is a design flaw. It should be secured in a manner that is removable without tools!
@786otto
4 жыл бұрын
Not really.
@joker-if4gu
Жыл бұрын
I Think some models have a pin, which makes it easier
@mercedemartinez2304
4 жыл бұрын
Es exelente
@mercedemartinez2304
4 жыл бұрын
Es perfeto
@ebbyt00
4 жыл бұрын
forgot to say ,Fill the condensate trap inside the water heater by pouring water water through the exhaust vent on top of the water heater until water flows through the condensate drain. page 31 in manual
@tonynguyen5362
4 жыл бұрын
What would happen if I didn't pour water into exhaust vent? I just DIY installed 240A and didn't add water through the vent, noticed few drop of water leak from the condensate outlet , very odd for non pressure line.
@ebbyt00
4 жыл бұрын
The water you add seals and prim the drain line ,if you don't,it might blow some exhaust gas out from drain untill eventually it primes itself
@edwardhamalian3569
3 жыл бұрын
Should there be a a check valve installed at the cold water intake?
@theredvillage5773
Жыл бұрын
No
@normanwells2755
4 жыл бұрын
Could someone explain the external recirculation? And where does the condensation line drain to?
@kenpeters5488
4 жыл бұрын
Condensate should be pipes to a neutralizer condensate pump then into a drain. And the external recirculation is for a fixture that's more than 50 to 70 ft away
@786otto
4 жыл бұрын
There are two models A with recalculation and S without, recirculation unit is able to recirculate hot water so when you open hot water will come right away it uses about 2 gas therms a month to do so, but you need another hot water line for it to work. S model you have to wait for cold water to drain from pipe first. Condensation occurs when the heat is taken from exhaust gases and has to be disposed of, it is a bit acidic so a filter is used so your pipes won't corrode.
@Order-in-Chaos
11 жыл бұрын
He was trained by robots. At least he sounds like them...
@Vasya797
9 жыл бұрын
/купил газ.котёл navien ace 20k turbo ... газовики заибали ,требуют чтобы я в котельный зделал дырку для винтеляции и чтобы труба это была выше крыши а там у меня мансарда высокая к чему крепить трубу не знаю да и у этого котла предусмотрено вентиляция... да ещё у меня ФОРТОЧКА есть
@elmono3939
3 жыл бұрын
haha... that ever sloppy PVC primer ... LOL
@MattFreytag
5 жыл бұрын
You failed to mention of this unit is hardwired in or plugs up to an outlet.
@paulputman2571
5 жыл бұрын
Matt Freytag an outlet
@michaelstaylor2844
3 жыл бұрын
@@paulputman2571 does it have to be a dedicated circuit?
@paulputman2571
3 жыл бұрын
@@michaelstaylor2844 yes sir
@paulputman2571
3 жыл бұрын
It needs a 110 outlet
@drdez
3 жыл бұрын
@@michaelstaylor2844 no
@xcmskim4
Жыл бұрын
Absolute garbage product. Go watch Mikey Pipes on KZitem. There is a design defect on the water tube heat exchanger which causes exhaust gases to leak