Opal Blue light while still full of water. This happens when the machine runs but no water fills an internal tank tripping a float valve within a certain timeframe.
This can happen for a few reasons:
pump needs primed
pump has gone bad
float switch is bad
-control board not sending power to the pump
My troubleshooting tested each part independently. -The float switch worked as it should. With the float down the middle pin connects with one wire and then the other wire with the float up.
-The pump functioned with an independent power source
-The purple plug on the Opal control board showed no voltage at any time. Tested with the float switch up/down, when just turning on in ice/clean mode and in all combinations.
Options for fixing the main board:
-send to GE Opal to fix for $250
get a new control board $150
bypass the board to power the pump (spare parts) utilized a old USB power adapter and changed the switches around.
Негізгі бет Opal Pump blue light while filled with water
Пікірлер: 33