HELLO EVERYONE. TODAY I WILL CREATE PROJECT communication PLC OMRON NX1P2 with HMI WEINTEK MT8071IE:
PLC OMRON NX1P2-9024DT CONNECT HMI WEINTEK MT8071IE (STATE SIMULATION )
+ HARDWARE PLC :- PLC OMRON NX1P2-9024DT VESION 1.40
- NX-series EtherCAT Terminal Coupler NX-ECC201(Remote I/O for EtherCAT):
* Digital Outputs:NX-OD5121 (16 OUT,NPN 24 VDC, 0.5 A/point)
* Digital Outputs:NX-OD4256 (8 OUT,NPN 24 VDC, 0.5 A/point)
* Digital Inputs:NX-ID5342 (16 Inputs, Standard speed, NPN 24 VDC)
* Digital Inputs:NX-ID5442 (16 Inputs, Standard speed, PNP 24 VDC)
- High-speed digital:I/O terminalGX-ID1611 + OD16:
+ HARDWARE HMI (SIMULATION) :- HMI WEINTEK MT8071IE
+SOFTWARE : * SYSMAC STUDIO VESION 1.47
* EASYBUILDER PRO VESION 6.08
+ CONFIG PLC OMRON NX1P2-9024DT
- CREATE PROJECT SOFTWARE SYSMAC STUDIO
- SET IP 192.168.0.123.
- CREATE FUNCTIONS BLOCK : "Ctrl_out_modul_data_word"
- CREATE SECTION :
+ MAIN
+ test_io
+ control_nx1p2_out, control_od5121,control_od4256,control_gx_od16
+ program_main_0
- create varible tag connect plc with HMI To connect the variable, we select
"Publish Only" mode in the Network Publish column in Data -Global Varibles
- EXPORT TAG OMRON
- DOWNLOAD PROGRAM PLC
+ HMI WEINTEK :
- CREATE PROJECTS CONNECT PLC OMRON NX1P2
- CLICK HERE :SYSTEM PARAMETER - DEVICE setting IP 192.168.0.123
- ADD TAG PLC OMRON
- CREATE SCREEN REGISTER ( PERMISSION ACCESS ADMIN , USER1, USER2)
- CREATE SCREEN HOME ( MAIN, TEST I/O )
- CREATE SCREEN PROGRAM MAIN
- CREATE SCREEN MAIN TEST I/O ( I/O PLC. I/O MODDUL NX_ECC201,I/O GX OD16-ID16
- CREATE SCREEN I/O PLC NX1P2_9024DT ( NX1P2 INPUT, NX1P2 OUTPUT);
+ CREATE SCREEN PLC NX1P2 INPUT ( 14 INPUT )
+ CREATE SCREEN PLC NX1P2 OUTPUT ( 10 INPUT )
- CREATE SCREEN MODUL ETHERCAT I/O NX_ECC201( NX_OD5121,NX_OD4256,NX_ID5342,NX_ID5442):
+ CREATE SCREEN MODUL NX_OD5121 OUTPUT ( 16 OUTPUT NPN )
+ CREATE SCREEN MODUL NX_OD4256 OUTPUT ( 8 OUTPUT PNP )
+ CREATE SCREEN MODUL NX_ID5342 INPUT ( 16 INPUT NPN )
+ CREATE SCREEN MODUL NX_ID5442 INPUT ( 16 INPUT PNP)
- CREATE SCREEN MODUL ETHERCAT I/O GX OD16_ID16 ( GX ID1611, GX O116 )
+ CREATE SCREEN MODUL GX_OD16 OUTPUT ( 16 OUTPUT)
+ CREATE SCREEN MODUL GX_ID1611 INPUT
-------- THANK YOU WATCHING ---------