For improving flame intensity what ahould command given in SADC. IS ryt approach to closed bofa
@kpatelbla
2 ай бұрын
I have explained this topic in detail video watch this one and ask question in comment section kzitem.info/news/bejne/toCOyHannGOTd5wsi=OresJzHxiP2a9dmZ
@gauravkr067
Ай бұрын
Water chemistry k bare m bataiye sir kitna ph, iron, turbidity, TDS conductivity maintain karte hai dm water m. Lightup k time water chemistry kiya maitain karte hai, CPU kab line m lete hai, function of CPU, COC of cooling tower kitna maintain karte hai or kyu?
@kpatelbla
Ай бұрын
Ok, will explain
@user-fr4rm2ih9n
2 ай бұрын
Sir ek vedio interview questions list par banaiye please
@kpatelbla
2 ай бұрын
Ok, next live will be about it.
@computercentre12345
2 ай бұрын
Sir for C elev voted second condution Feeder c service and CD elevation oil gun in service and 110v ac power failure. Is feeder c service necessary for acting C voted. If feederC not in service and (Cd gun service and 110V AC fail) then also C should voted?
@kpatelbla
Ай бұрын
Feeder C should proven for more than 2 second to arm NO FLAME VOTING CONDITION
@Ranjitamaharana-xu6sg
2 ай бұрын
Sir please make video for Boiler and Turbine Emergency Handling
@kpatelbla
2 ай бұрын
Live stream already available on my channel
@computercentre12345
2 ай бұрын
Sir why hotv lotv has 220v DC power not 110v AC power?
@kpatelbla
Ай бұрын
Yes 220V DC
@0503manoj
2 ай бұрын
Sir Hotv me kitna volt supply hota hai Aur Lonv m kitna volt supply hota hi
@kpatelbla
2 ай бұрын
LOTV 220 v DC., LONV 110 Volt AC
@abhishekmishra-nv3lf
2 ай бұрын
Why lovt hotv220 Dc and lonv and honv 110v ac sir
@kpatelbla
2 ай бұрын
@abhishekmishra-nv3lf it is to initiate MFT in case of 110 Volt AC failuire
@Ranjitamaharana-xu6sg
2 ай бұрын
Sir If One Vacuum pump in Permit and at that time other running Vacuum is Trip then what will be action taken at that time.
@kpatelbla
2 ай бұрын
If there is only two vacuum pump then immediately reduce load to save unit corresponding to vacuum.
@abhishekmishra-nv3lf
2 ай бұрын
Load reduced 40 percent
@vikaskumar-fq4uy
2 ай бұрын
@@kpatelbla Sir i think unit will be trip on high vaccum in case of vaccum pump tripped
@kpatelbla
2 ай бұрын
@vikaskumar-fq4uy if this is for more than 15 minute.
@vikaskumar-fq4uy
2 ай бұрын
@@kpatelbla sir but vaccum will drop very fast, I don't think that it will take 15 minutes
Пікірлер: 28