TO RESET WITHOUT KNOWING THE CODE: unplug the keypad power (i think its a 12 pin 6x2 black molex type) then from that plug, find the wires coming off the end of it that are BROWN, WHITE, and WHITE WITH YELLOW STRIPE. Cross those 3. (Strip them and wire nut/twist them together) Then plug the device in once you have them connected. This will put you into programming mode. from there type 1# (NEW CODE) * (NEW CODE) * and then * to exit. all done.
@alanmendoza9509
Ай бұрын
When trying to reprogram the relay time the door just immediately shuts, it only gives one second to open the door, and I already tried factory resetting the keypad to turn it back to it's original 5 second factory set relay time it still immediately shuts
@shannonpeebles113
2 жыл бұрын
Thanks for posting. What does it mean for the master code to be stored in 1? If you forgot your code; how would you access the master code in order to start over and create a new code?
@7pixl607
2 жыл бұрын
User codes are stored in slot numbers so you have to write down what code is assigned to what slot number to edit/delete the code in the future. If you don't have the master code then you have to reset the keypad by taking it off the wall and pressing the SW1 switch then 46# 00000 # 00000 # ** that puts the keypad back into the default out of the box state. Hope that helps.
@FEBRIZIOtv
Жыл бұрын
TO RESET WITHOUT KNOWING THE CODE: unplug the keypad power (i think its a 12 pin 6x2 black molex type) then from that plug, find the wires coming off the end of it that are BROWN, WHITE, and WHITE WITH YELLOW STRIPE. Cross those 3. (Strip them and wire nut/twist them together) Then plug the device in once you have them connected. This will put you into programming mode. from there type 1# (NEW CODE) * (NEW CODE) * and then * to exit. all done.
@adamnasher944
Ай бұрын
I was able to add a user code but couldn’t change master code(1234) I did 99#1234*1234* and it didn’t go to programming . I press the rest button in the back it activates the relay and go to green . Thank you for your help ✊
@Aprilmayjune1998
11 ай бұрын
Hello! Do you know how to do an all user lockout?? Where let’s say after business hours I want it locked out to all codes, and then how to unlock it?
@nancytervalon2274
Жыл бұрын
SECOND RELAY STOPPED WORKING My keypad was operating two relays, a walk-through gate and a drive-through gate.The code to open the drive-through gate suddenly stopped working. I used the command: 59#2#user location#code*code*. 2 is the drive--through gate relay. I used another 2 for the user location. No luck. Any idea what, if anything, I did wrong?
@anthonykeemle6826
Жыл бұрын
How do i erase all current codes? Even after changing the master code i still can access with other valid codes
@EnergeticPanda
Жыл бұрын
I hope I could get a message back; I want to program the keypad in instant so once the door opens and it closes I want it to lock right away how would I do that?
@7pixl607
Жыл бұрын
Hello, I looked through the programming manual and there doesn’t seem to be an option to relock on door closing because the keypad doesn’t have a door contact input. You would need a full fledged access control panel to accomplish what you’re looking for.
@EnergeticPanda
Жыл бұрын
@@7pixl607 do you have a number I can send you a video or a social media platform I can send you a video of what I’m meaning?
@7pixl607
Жыл бұрын
@@EnergeticPanda our Twitter is @7PiXL
@rochelschecter9142
11 ай бұрын
How do I delete previous code
@paulfairfield4880
10 ай бұрын
Do a search for IEI 212 manual. I think it’s toward the back of the manual, but it will explain how to erase all codes. I think there might me some re wiring
@aliale9720
2 жыл бұрын
I don’t have the master code. Please help.
@7pixl607
2 жыл бұрын
Take the keypad off the wall, press the SW1 switch then 46# 00000 # 00000 # ** that puts the keypad back into the default out of the box state.