Hello, and when we don't have observation wells, what are the procedures?
@WaterServicesandTechnologies
6 ай бұрын
Thank you for your interest, for pumping tests it is one of the test premisses to have an obsevation well.
@meucanal-NG
6 ай бұрын
In this case you can use a fake well radius and pretend that the observation well is, say, 0.1m from the well. In this case the values obtained for Transmissitivity is valid as it is not dependant on the distance between the well and the observation well. However the value for storativity has to be discarded as it is not realistic. Thats why you can ave single well tets, such as slug tests or packer testa to obtain T,or K. But they will not provide S, Ss or Sy. Also, of course you can use single well tests to calculate well head losses and well efficiency
@jemmyotieno9101
6 ай бұрын
Which software are you using to come up with the graph
@meucanal-NG
6 ай бұрын
It is built in AquiferTest itself
@wahyubyl
3 жыл бұрын
Could i have the presentation material?
@lallitarim8286
3 жыл бұрын
i want it too
@WaterServicesandTechnologies
9 ай бұрын
Thank you for your message. Please send us an e-mail to vendas@waterservicestech.com and our team will respond to your request.
Пікірлер: 8