Do you also need a backflow preventer? I live in Southern CA where we are required to use above grade anti siphon valves. Is a backflow preventer overkill?
@Andy_Humphrey
Жыл бұрын
@terrireyes295 most likely, yes. I wound check with your local water authority for the code in your area.
@lcrobert3911
10 ай бұрын
nice video... mine says 150PSI on it. I cant find one online with that spec... its just for a normal sprinkler system, do i need that high of a rating?
@Andy_Humphrey
10 ай бұрын
Thanks for watching! For a residential system, 60psi at the backflow preventer is generally adequate. The 150psi could be the max rating, as opposed to the regulated psi - hard to say. If you can txt us a picture we'd be able to look deeper. TXT: (833) 343-4590 ~Andy
@lcrobert3911
10 ай бұрын
OK thank you, it does appear that the 150 is the max rating, but i cannot tell the nominal pressure, it must be 30 or 40. AS is the case on mine, it appears there is a common issue of the little white button (looks like a one-time relief valve) that requires you to replace the whole assy if it pops. Picture sent to your text number. I appreciate your help. @@Andy_Humphrey
@Andy_Humphrey
10 ай бұрын
looking forward to seeing the picture - haven’t received anything yet - we’re standing by to assist 😊
@lcrobert3911
10 ай бұрын
I sent to the number you gave me
@eddiehuertam6
3 жыл бұрын
Thank you for sharing. Do you have any videos or documentation on replacing one? The plugs near the flow symbol blew out on 1 of my 6 pressure-regulating filters.
@Andy_Humphrey
2 жыл бұрын
We haven't created a video for that process as of yet and I wasn't able to find any documentation, but it's a simple process. Be sure to purchase the exact same brand and model that you currently have, turn off the water, unthread the existing unit, and thread in the new unit. There's nothing particularly magical about these, just make sure that everything is tight when you install it and don't overtighten and risk breaking it. Run the zone after installing and check for any leaks.
@carlosa.avalle528
Жыл бұрын
My PRF075RBY has a minor leak on the white button, it is new, no cracks or apparent defects on the unit. Specs state that the unit can handle up to 150 psi, the incoming pressure is 95 psi. Is this leak normal when under that kind of pressure?
@Andy_Humphrey
3 ай бұрын
Great question, unfortunately I’m not sure. We get this question a lot and I need to find the answer!!
@carlosa.avalle528
3 ай бұрын
@@Andy_Humphrey I returned mine, regardless of it being normal or not it doesn't do much good if it leaks. My question was in case it was a defective unit but w/ no reply to my question forthcoming from the manufacturer you go to the next guy.
@vladimirjara8045
2 жыл бұрын
What happens when the white plug blows out? Can we replace the plugs or do I need to buy the whole unit?
@Andy_Humphrey
2 жыл бұрын
Great question. That piece of the filter is the pressure regulator. Unfortunately I don’t have an answer for you when it pops out. Perhaps someone else will comment here and provide a solution.
@progrockwannabe
Жыл бұрын
How do you tell the difference between one that has just the filter and one that has both filter and regulator?
@Andy_Humphrey
Жыл бұрын
Most filters (in the world) do not have pressure regulators…so that narrows it down a bit. For Rain Bird specifically, the white dot is a giveaway.
@iyorek
3 жыл бұрын
Hi. Thanks for the info about the 2 rainbird pressure regulators. I currently have one in which the cap is not sealing due to a broken o-ring. I've been doing my best to replace just the o-ring with a correct size. Is this possible or do I have to completely replace the whole filter?
@Andy_Humphrey
3 жыл бұрын
Those filters are relatively inexpensive, and getting the correct sized o-ring can be tricky, as Rain Bird doesn't offer them as a separate part. We'd personally bypass the trial and error and just purchase a new unit and replace the old one.
@AXNJXN1
2 жыл бұрын
@@Andy_Humphrey This is the MOST TERRIBLE way of doing business! Shame on Rainbird for the fallacy of not producing a SINGLE line item simple gasket replacement option! Absolutely despicable that this isn't an option. Shows how far Rainbird goes to simplify the customer's pain.
@vladimirjara8045
2 жыл бұрын
Just put Teflon tape and it will work.
@loulupero4147
3 жыл бұрын
Thanks for information. Will 3/4 reducer 1/2 “ pipe still be effective?
@Andy_Humphrey
3 жыл бұрын
Hi Lou - great question. Yes, you can reduce a 1" RBY down to 3/4". Keep in mind that the pressure regulation feature on the 1" has a flow range of, 3.0 to 15.0 gpm, so any flow less than 3.0gpm will not be pressure regulated. If your flow is within the 3-15gpm you are just fine!
@Danny-ez3pm
2 жыл бұрын
@@Andy_Humphrey How do we replace the white plugs? Mine blew out
@lcrobert3911
10 ай бұрын
they dont seem to wanna answer that one.... but looks like it is a safety device that fails often, then you need to replace the whole gizmo..ugh! @@Danny-ez3pm
@katicakalinic2346
2 жыл бұрын
Please tell me how to fix licks thru white plugs by side’s
@Andy_Humphrey
2 жыл бұрын
Hi Katica. The small white plug is where the pressure regulator is installed. Has the device always leaked since it was originally installed? If yes, perhaps the flow (gpm) or pressure (psi) is out of specification, too high. If it just started to leak, perhaps the plastic has a small crack and the unit needs to be replaced. Also check the filter and see if it needs to be cleaned, perhaps this is causing some back pressure. Give us a call and we'd be happy to chat through it with you. -Andy
@kirstinbrennan
2 жыл бұрын
How do I connect this to my hose?
@Andy_Humphrey
2 жыл бұрын
Hose threads are different from the pipe thread that these filters have, so the first step is to adapt from the hose thread to the pipe thread. You can do that with this fitting from our store: sprinklersupplystore.com/collections/garden-hose-fittings/products/orbit-brass-swivel-hose-fitting If you purchase a 3/4" filter, it will thread directly into this fitting.
@19cream832
2 жыл бұрын
It’s still reading over 70 psi and dropping my pressure. I don’t know what I did wrong. The thing flat out doesn’t work
@Andy_Humphrey
2 жыл бұрын
Hi Nick. Double check the the flow rate (gpm) of the zone is within the range of the device. Too much flow could cause it not to work properly. Perhaps you need a larger size. 3/4 inch = 5.0gpm max 1 inch = 15.0gpm max
@emmanuelrabson5942
2 жыл бұрын
So if I have 1 inch filter and I only have 20 tubings there is no need for pressure regulator
@Andy_Humphrey
2 жыл бұрын
You should first check your incoming pressure. If the pressure is less than about 50psi you likely do not need a pressure regulator. Most drip devices (emitters) are pressure compensating over a wide pressure range, and the goal of the pressure regulator is to hold the fittings together without the need for clamps. Happy to help if you need anything.
Пікірлер: 32