Hey Darrell I'm doing an internship in an enterprise for the thesis degree. I'm using the MPB10 sensor connected to a SIG200 to analyze the vibrations of a cylinder driven by an electric motor in different conditions. I'm using the REST API in order to take out the different values interesting (such as frequent and dominant peaks) through the ISDU parameterization. I searched some tutorials on the internet and I saw that there is a well-done "application" that you access with SOPAS (the SDD file of the MPB10), the one you show in the videos. Now I see that you connect the sensor with the SILINK2 Master directly to the computer in order to use it. I tried different methods to use the application, but since it doesn't detect the sensor I cannot use it. Is there another way to use that already-made application/tool without the SILINK2 Master? I'm asking it because I don't have it (from what I understood is kinda an adaptor M12-USB that also gives power) and I really would like to collect, process, and analyze those data more easily. Thanks a lot.
@WonKiLee-z6i
Ай бұрын
I also want to monitor the data of MPB10 by connecting MPB10 to SIG200 in the same way as you. But I can't connect MPB10 to SIG200. Can you tell me how you did it?
@darrellbrogdon885
Ай бұрын
There are a few different ways you can do it. Either with an Si-Link master(PN 1061790), through the logic editor, or over a communication like REST API. I've done it before as well with Excel and an API call. For example, once you have the IODD file in the Master just use the following API Call(Of course you'll have to use a different IP address)... Http://192.168.1.23/iolink/v1/devices/master1port1/processdata/getdata/value?format=iodd