Wouldn’t that first capacitor need replacement for testing too high
@hvacrnortheastern2110
Жыл бұрын
Welcome from Connecticut this reminds me back in the early 2000 l did service in Rhode Island had Rhode refrigeration license .We did Supermarkets the company l use to work for we service three state.
@mikerefrigeration5736
Жыл бұрын
Nice. Im curious to see how it is working in supermarket refrigeration
@hectortorres542
2 ай бұрын
Should have sold them a new walking box with a new condensing unit and Evaporator, What a filthy walking box.Unfortunately this is what you run into. Health department time
@seadeas
6 ай бұрын
May I ask, what did you charge for that job? No competition, just wondering? Thanks
@MariosACandRefrigeration
Жыл бұрын
great job,thanks for sharing.
@mikerefrigeration5736
Жыл бұрын
Thanks for watching!
@taozhang5522
Жыл бұрын
Why pressure test 100psi. Should be higher ?!
@mikerefrigeration5736
Жыл бұрын
100 psi is fine when you are working with old equipment. You dont want to cause a leak by overpressureizing old equipment. The evaporator was about 40 yrs old. Also 100 psi pressure test is fine when you have digital gauges wigh higher resolution.
@HermesVintage
Жыл бұрын
Aye I have the same fluke meter 😎
@kenallen9470
Жыл бұрын
How were you checking liquid level in the reciver with your map gas?
@hvacrnortheastern2110
Жыл бұрын
That the way you got be careful warm up receiver run you hand over receiver where it’s cold that’s where the level inside the receiver.
@kenallen9470
Жыл бұрын
@HVACR Northeastern thanks man, totally new to me lol gonna use that
@mikerefrigeration5736
Жыл бұрын
Heat the side of the reciever from top to bottom for about 10 to 15 seconds. Feel it with the back of your index finger. If its hot its vapor. If its cool then its liquid. If you have fan cycle control, make sure you pump the system down before you check. If youre reciever is hot at the bottom you are very short of refrigerant.
@kenallen9470
Жыл бұрын
@@mikerefrigeration5736 amazing thanks
@mikerefrigeration5736
Жыл бұрын
@@kenallen9470 no problem. Sight glass only tells you that you have enough liquid refrigerant to reach the dip tube inside the reviever. Units with a head master will need additional refrigerant in winter time.
@shine-cg9uf
Жыл бұрын
👍🇺🇸💪❄️ Great vid thanks. How high is too high for start cap reading?
@hansmuller1625
Жыл бұрын
Depends on the compressor, always check the manual. But caps are generally not very precise components in this context. +20% or so is fine.
@shine-cg9uf
Жыл бұрын
@@hansmuller1625 thanks for the feedback, much appreciated 👍