Thanks for the video. I'm thinking of installing an Asco Sirai pressurestat im Oscar 2. So, basically you cut the original wires, put new cable lugs with a grimping tool and then plug the lugs in the Sirai pressurestat?
@plurplursen7172
7 ай бұрын
Ehm, yes it's the valve. Because half of it are missing.
@84DavidM777
2 жыл бұрын
Nice videos. Thanks for sharing. You answered like 30 questions I had. Just got a Oscar one and thinking of moding the heck out of it.
@Ishmaellllllllllllll
15 күн бұрын
I have a ceilware machine and rn the pressure valve is blowing out water allll the time now after I replaced the pump after it was seize
@trailing123
3 жыл бұрын
I just blew our rocket coffee machine this morning by spilling water on the top of the machine 😞 it was great to see your Vlog , thanks for posting
@AbuAlfadl-GTR
2 жыл бұрын
I guess this machine need full descaling first
@Pauly5150
9 ай бұрын
Great videos. I have wanted to have a go at repairing an old machine, and this the kind of help that is perfect. Once I find a donor machine for a bargain that is. Thanks
@EDGARMPIKAMEZO
6 ай бұрын
Remember not all the time the pressure safety valve has to be replaced after it discharges, sometimes it is its normal operation especially when the pressure it's beyond 2 bars. Sometimes try just to adjust the pressure switch or replace it
@coastcafeequipment
6 ай бұрын
Correct. But not in this case
@OsvaldoAssispereirra
2 ай бұрын
Tradução em português
@andrewcarnill4749
24 күн бұрын
Did you use thread tape on the pressure stat threads?
@coastcafeequipment
24 күн бұрын
@@andrewcarnill4749 yea
@fredericl6190
2 жыл бұрын
Hi, is 0.9 bar enough for an heat exchanger machine ? I’ve seen more often 1.2. Thanks.
@lenovo7999
2 жыл бұрын
Sure but maybe not so great for steaming
@ramsubedi2290
Ай бұрын
❤
@chickenpox7122
2 жыл бұрын
Nice video❤.Can you make a video about how to replace the pressure valve of the crm3005e ? Thanks.
@eliranelkiess7811
2 жыл бұрын
Hello how can we change headlight bulb for rocket appartamento? thank you
@IanLandesman
9 ай бұрын
Only because of your video did I think to check if my pstat line was full of water when it wasn't turning off heating element and machine would shut off so to temp safety switch. $0 fix. Guess I have to purge it every few years. Thanks!
@coastcafeequipment
6 ай бұрын
Shouldn't have to, as long as the water level is set correctly and you clean the water level sensor every 6-12 month
@chulolo997
9 ай бұрын
The level probe stick will not tighten even after I screw the bolt, why is it? Yours seem to stabilize at any height that you like
@coastcafeequipment
6 ай бұрын
Perhaps the plastic sleeve has fallen down
@JasonAlexzander1q47
3 жыл бұрын
How often does that pressure valve go bad and need replaced?
@hugobot5
10 ай бұрын
really easy to follow , info and method really helped me with a totally different problem , will look thru your other vids too , my current prob is old Astoria Argenta single not heating ...
@coastcafeequipment
9 ай бұрын
Check over temp, element , pressure state
@RMD992-f2n
11 ай бұрын
How do you remove those cables and wires attached to the pressure stat I just can’t get them off and I’m pulling very hard
@coastcafeequipment
11 ай бұрын
Use a flat head screwdriver to lever it out
@RMD992-f2n
11 ай бұрын
oh by the way i got the cables off but now i cant twist off the pressure stat it seems like its seized or something? ive applied so much force that i actually broke the old pressure stat. how do i remove it is it supposed to easily twist off? i've tried evreything...@@coastcafeequipment
@andrewshiner1606
2 жыл бұрын
Thank you for your video. Do you know what the boiler is made out of? I can't tell if its coper that has been plated or if its something like aluminum or stainless steel.
@pascalbondon2308
Жыл бұрын
It is made of copper. After a few years, the color of copper turns greyish or greenish but it is copper.
@JasonAlexzander1q47
Жыл бұрын
Could this also be responsible for low pressure at the brew head?
@pascalbondon2308
Жыл бұрын
It should have minimal effect on the brew pressure because the pressurestat only allows a narrow range of pressure variation (0.5 to 1.2 bars) in the boiler.
@bjrnvesthansen6083
2 жыл бұрын
Think you’ve got it the wrong way around. It’s your anti vacuum valve that’s leaking. The one with the pin is the safety valve.
@coastcafeequipment
Ай бұрын
The one w the pin is the anti vac valve. The anti vac valve doesn't blow like that. Only the safety valve does that