Thanks for the video! I never thought of having the toilet last in line. Makes sense! (I'm just a homeowner)
@joephillips6634
Жыл бұрын
This was a strangely useful video for me. I like how you explained why you did things.
@davidunderwood4341
Жыл бұрын
I appreciate your comment. We're going to do have more videos on the main plumbing drains coming up soon.
@babyboinews6896
2 жыл бұрын
@Dave Underwood good job on the plumbing I'm a fellow Michigander
@jimmyfavereau
5 ай бұрын
Gold! , thanks David!
@davidunderwood4341
5 ай бұрын
You're welcome.
@BelleRiverHeating
2 жыл бұрын
Dude I like your knowledge, I like to put the toilet last because the cleaner more solid free water washes it down.
@davidunderwood4341
2 жыл бұрын
Thank you! Right on!
@torempilor
3 жыл бұрын
For the basement bathroom, so that ends up going into a sanitation pit, then pumped out to the septic? Very interesting, you will have to cover that equipment when you install. I guess I thought the septic lines would be below the basement footer but they must be above. Great work!
@davidunderwood4341
3 жыл бұрын
Yeah, unfortunately the septic main is higher. I'm not a big fan of ejector pumps either.
@davidunderwood4341
3 жыл бұрын
I said 3/8 long bit. I meant 3/8 bit that is a long bit! Lol!
@RaistlinVideos
3 жыл бұрын
Nice work. Gotta get it right, because once concrete goes down it ain't moving. :) Curious to why you're adding a vent for the toilet? Isn't it already vented from behind by both of the 2" shower and vanity vents? Could be different where you are, but I'm pretty sure our code requires the toilet vent to be within 6'. Not that it matters in your case as you have the equivalent of a 4" wet vent within 3' already.
@davidunderwood4341
3 жыл бұрын
Thanks for your comment! It's funny because I've had people troll this video with comments saying it's under vented! You are correct though! It is already vented enough without the other one added. I just figured why not add it because I know a wall is going there anyways and that I could always cap it if not used.
@beckyschwantes5287
3 жыл бұрын
I have seen this before . What is the idea behind the box at the shower?
@davidunderwood4341
3 жыл бұрын
@@beckyschwantes5287 After the concrete is poured, it gives you an access to hook up the bath tub later. It's almost impossibe to install the tub pipe in the perfect spot before hand. Thanks for commenting!
@999raiderz
2 жыл бұрын
The vent is required to be a certain distance from the trap…
@davidunderwood4341
2 жыл бұрын
@@999raiderz Yep!
@keeganaxtell231
3 жыл бұрын
clean glue joints!
@davidunderwood4341
3 жыл бұрын
Thank you so much for noticing! Means alot!
@khaleefax9553
2 жыл бұрын
*OK, so for my under the floor piping under the basement floor, that will take all the waste water into the sewer line, I am thinking to put a 5 inches schedule 80 pipe. Cost doesn't bother me. Are there any drawbacks for this application? I just wanted to have a stronger and wider pipe under the floor so I, hopefully, never have to dig the basement floor to treat the broken or narrow pipe.*
@davidunderwood4341
2 жыл бұрын
Overkill is always better.
@999raiderz
2 жыл бұрын
When it comes to sewer, bigger is not always better. The liquid can move more quickly than the “solids”, thus…not draining properly. You really should consult an experienced plumber on this.
@davidunderwood4341
2 жыл бұрын
@@999raiderz I'll be fine.
@davidunderwood4341
2 жыл бұрын
@@999raiderz You have no clue how much experience I have.
@davidunderwood4341
2 жыл бұрын
@@999raiderz Slope is more important than size. Size has nothing to do with it.
@omegaplumbing
6 ай бұрын
Need a trap primer technically
@Doubl3N
Жыл бұрын
How come you didn't use a P Trap? Is the venting enough? I'm about to rough in my basement and I'm a little confused on this.
@davidunderwood4341
Жыл бұрын
A P trap will be at every fixture once the bathroom is put in. A toilet comes with its own built in P trap. The bathtub's P trap will be installed in the access box, the sinks P trap will be in the future wall that's built. Thanks for your comment!
@davidunderwood4341
Жыл бұрын
The venting is completely separate from the P traps. P traps hold water in place after draining so sewer gases are blocked from coming into the house. Vents protect the P traps from being sucked dry while the water is draining. The vents accomplish this by keeping the air pressure at a neutral atmospheric pressure. A great analogy is the small air inlet on a gas can. Hope this helps!
@omegaplumbing
6 ай бұрын
I think people should preface the videos with where they are and what code they use
@davidunderwood4341
6 ай бұрын
You could always make one for us!
@gregorysampson8759
3 жыл бұрын
Why not put the lav clean out tee above the lav drain t. Rather in another room.
@davidunderwood4341
3 жыл бұрын
Good question! That way the clean out will be hidden in the wet bar base cabinet on the other side of the wall instead of being seen in the batheroom wall.
@irfanalisiddiqui6082
2 жыл бұрын
why not use 4 inches pipe for toilet drain?
@davidunderwood4341
2 жыл бұрын
Not needed.
@gregorysampson8759
3 жыл бұрын
Galvanized for gas line!???
@davidunderwood4341
3 жыл бұрын
For 10 inches just until it enters the house. What would you recommend? The gas meter itself is galvinized piping. I must be missing something and want to make sure It's done safely and correctly.
@waynecurr9569
3 жыл бұрын
100% proper !Exposed to the elements = galvanized !
@chrisviolette8991
7 ай бұрын
Sanitary ts can not be used on there back every fuxture needs a vent
@davidunderwood4341
7 ай бұрын
In this case it could be. It would have been better for you to have listened in on the discussion I had with the inspector. After our detailed talk about the exact subject, he happily gave me the green sticker.
@davidunderwood4341
7 ай бұрын
In a case where an additional drain line could never be added to the vent later on, when the concrete grade is an issue with a Y on its back. Sometimes codes can be overlooked. Straight from the inspector's mouth. The venting air doesn't know the difference. In 99.9% of other situations, your comment is absolutely true!
@TeslaBoy123
2 жыл бұрын
U have tub and toilet but where is bath sink drain 🤔
@davidunderwood4341
2 жыл бұрын
Hey, thanks for commenting! The drain for the sink comes off of the 2-inch vent pipe. We couldn't come up out of the floor because of the stanchion pole footing.
@rogerbeaird3320
2 жыл бұрын
Its 10feet
@rogerbeaird3320
2 жыл бұрын
Thanks for the video bro
@davidunderwood4341
2 жыл бұрын
@@rogerbeaird3320 Thank you!
@diegovega6545
2 жыл бұрын
I DON'T KNOW BUT THE 2 INCH VENT FOR THE TOILET IT,S KINDA FAR WHY YOU DON'T INSTALL THE BATHROOM PIPE PROPERLY VENT FIRST AND THEN THE TOILET WITH A VENT THE WAY IT'S LAYOUT LOOK'S LIKE YOU MIXED THE DRAINS WITH THE VENT'S I MAY WRONG , BUT IT'S JUST MY OWN OPINION .....GOOD JOB ANY WAY 👍
@davidunderwood4341
Жыл бұрын
The vent is close enough. I gotta green sticker on it. Thanks for the comment. I just uploaded 2 more videos on our main house drain plumbing if you wanna check them out. Thanks again.
@babyboinews6896
2 жыл бұрын
@david Underwood are you a plumber
@davidunderwood4341
2 жыл бұрын
I'm a Real Estate Investor.
@babyboinews6896
2 жыл бұрын
@@davidunderwood4341 who taught you plumbing my friend
@davidunderwood4341
2 жыл бұрын
@@babyboinews6896 I taught myself as well as being surrounded by plumbers. Also bought the Plumbing code book and studied it.
@babyboinews6896
2 жыл бұрын
@@davidunderwood4341 awesome could you tell me what is the newest code book to get I'd appreciate it
@babyboinews6896
2 жыл бұрын
@@davidunderwood4341 don't mean to keep bothering David but did you receive my last message about what is the newest code book to ger