aik setting ap miss kr gay.. professional settings-function settings may aik option hay "only PV power Load. Is ko enable krnay say direct PV pay load chala saktay without grid and battery
@energyshiftsolarservices
12 күн бұрын
Backup 2 k Sath smart load option bhi thi is k bary men batain
@bigvaporpk8568
2 ай бұрын
Solax inverter hybrid 6kw low price 263k and Very user-friendly easiest setting. Other all inverters very difficult
@MuhammadAli-ui9rm
21 күн бұрын
Without batteries ghar ka load chala sakta hai yeh inverter?
@muhammadibrahim1541
7 күн бұрын
i need help: Backup 2 load or (smart load) ye soliscloud app mein show ni ho rahi just bluetooth k through connect ho to show hoti hein any solution?
@techchat370
2 ай бұрын
very nice M.A
@ADILKHAN-kp7bi
2 ай бұрын
Bhai meny 6kw ka solis hybrid liya he or me battery use nhi krna chahta lakin issue ye a rha k jesy hi load shedding hoti he mera inverter b off ho jata he eska koi solution? Me battery b nhi lgana Chahta or na hi green meter. Please guide me
@eagletech4234
2 ай бұрын
Din k waqt trip nahi ho ga ....agar aap tottal 6 kw Hy to 2500 watt Sy 3000 kw handle ker ly ga wo b soft load pe yani fan lights ho to or agar torque load din ko b howa jhatka load howa to trip ker jae ga lekin Raat ko Must trip Kary ga ku k yeh 2 source inverters han
@Sample-m3w
12 күн бұрын
3k my ap ki setting kar du ga
@aftabalam67
Ай бұрын
Salam Brother, i have 8kW Solis hybrid inverter. the setting is same as yours. when the grid is off the inverter works fine and after turning on grid, the solar power comes down to zero and the grid takes all the load, despite the setting is on self use. please guide whether it is wiring issue or setting need to be changed.
@Sample-m3w
12 күн бұрын
Mujay btahy kya issue a raha?
@Sample-m3w
12 күн бұрын
3k my ap ki sari setting kar du ga
@techchat370
2 ай бұрын
CT lagany ka sahi tareka bhi upload krain complete k kahan kahan lagai ja sakti hai kis kis scenario main kahan lagay geee. grid load par kahan lagay ge or only backup load par kahan lagay ge ct.
@AtifRehmaniwaamtech
Ай бұрын
Can you check my 8kw inverter setting
@user-yr2cw6sb6e
2 ай бұрын
What is the grid side? And why there is no consumption on grid side
@qadirahmad8951
2 ай бұрын
Thanks brother, how can we change Charging & Discharging Slot after its first time setting
@SSG-if6zj
2 ай бұрын
Mery inverter ki 1 port chalti hai dosri ni chalti Or mery pas batry ni hai jub wapda jata hai to inverter off ho jata hai is ka kia seen hai
@wassaufkhalid8593
Ай бұрын
Battery bagher sirf backup load ki port chalti ha
@MuhammadAli-hh2ml
28 күн бұрын
@@wassaufkhalid8593 nahi mere pass to dono port chal rae without battery
@digitalworldsign9
2 ай бұрын
Battery charging setting aap ny dono charging wali rakhi hain discharge option use mahi kiya . Why ?
@saeedkhan8045
2 ай бұрын
Can this inverter be used off grid?
@shahzadnazshahzad
2 ай бұрын
Salam g, sir Solis 5kw inverter Ki setting ka bta dain
@wassaufkhalid8593
Ай бұрын
Ye CT direction and ratio ka kia matlab ha
@mohammadsyed7915
2 ай бұрын
PV available honay k bawjood grid side se load le raha hai mera s6 8kw...kya issue hai?
@wassaufkhalid8593
Ай бұрын
Same. Kuch pata chalay to bata dein. 2 to 3 amps hamara leta ha solar K honay K bawajood
@wassaufkhalid8593
Ай бұрын
App mein show karta K sirf solar use ho Raha and inverter K sath device pe 2 to 3 amps
@Rizo00.
2 ай бұрын
Bro.. ap kis city se h.. mn ye model lae chuka hun lakin eski setting ni ho rhi.. plz eski 1 br setting krwa dy
@Sample-m3w
12 күн бұрын
G bhai mujay btahy.. Kya issue a raha...
@aftabsiddiqui7134
2 ай бұрын
Sir agr installer ko hi samjh na ati ho setting ki to owner k pass Kya option he😢 4 month se Mera Solis 6 KVA hybrid set hi ni ho Raha . Pata hi ni chlta Kitna load ghr me use ho Raha he aur Kitna export ho Raha he grid ko
@mobeenmurtaza2693
2 ай бұрын
Serial num yaha send karo... Ma check karta hoon
@deltasolarpower
2 ай бұрын
Bhai g ap ki SBU wali setting kam ni kr rhi ? Plz answer
Пікірлер: 32