Record le kar kya achar dalunga.... Sc test se kya fyada hua yeh batao hamare copper losses kitne huwe yeh batao
@surendrakverma555
9 ай бұрын
Very good. Thanks Sir 👍
@Shivkumar-qp9wv
2 жыл бұрын
I love ur vedios
@ashokmosun4204
2 жыл бұрын
Good information 👍
@InderjeetSingh-pe7ou
Ай бұрын
Aapke dwara batai Hui video ke Madhyam se Jankari bahut hi acchi lagi lekin Hamen yah Kaise Pata Chalega jo result Aaye Hain vah sahi hai ya galat hai is Vishay Mein aapane Koi Jankari Nahin Di
@nandaramvarma6945
2 ай бұрын
❤❤❤❤❤❤❤❤❤
@himanshusekharparida1489
Жыл бұрын
Sir ,how to know this value comes for the test is correct or not ,if faulty trafo what value comes
@hafizimranrafi452
11 ай бұрын
Thanks for this informative video. Is there a calculation/ formula for this test? If yes, plz share.
@akashsenta3601
Жыл бұрын
Respected Sir, Please explain how to find LV side short circuit current of Dyn5 trasformer.
@zarghamkhan8288
Жыл бұрын
Ampere capacity of fuses (for both HV side & LV side) and MCBs capacity may please be inform?
@excellentelectricalknowled6672
Жыл бұрын
Sir lc side r,y,b,(51.70,51.90,51.5) amp current flow ho rahi hai ,,,lv fuse side short kiye hia to ,,,aapas me short nahi honge...pls reply
@Insighttecs
Жыл бұрын
yes, thats why it it called short circuit test, but, we test it on 440v. so, there will no any damadge to the transformer.
@praveenkumar-uu6ht
Жыл бұрын
How many tap having in transformer sir please told me
@rajkamal1405
2 жыл бұрын
Synchronizing panel and AVR PANEL KA WORKING PE VIDEO BNAYE
@bhaveshpatel1289
11 ай бұрын
Dear sir chotaliya De ugvcl 10kva to 200kva testing karva hoi to material requirements
@deepaksonawane787
6 ай бұрын
Short circuit mein neutral mein jyada Karan a raha hai N-9.5 22/11kv usko kya karna kya karna
@Insighttecs
6 ай бұрын
may you have provided nutral of source to the neutral of transformer...
@b.saisankarachary8644
2 жыл бұрын
Please sir Explain all testing of PTR ( Tan delta, Winding resistance, Turn ratio test , vector group test) and also share why we do this all type of test in PTR and how to know this value is correct ?
@dhanjibhairaval5072
Жыл бұрын
P
@vinodp8621
Жыл бұрын
Why we conduct this test and what is the use if we conduct?
@mdnadeemhussainansari6770
2 жыл бұрын
What is the size of cable and fuse we need to during test At time of testing huge current will flow during that time
@Insighttecs
2 жыл бұрын
The huge current flow only at LV side during short ckt current test. LV side cable should be 10 Sqmm required, But the test is conduct for maximum 15 to 20 sec. So, 4 Sqmm cable can take the load for that time.... And fuse to be taken 60amp at LV side... Thanks for watching 🙏
@anilkumarshah4523
Жыл бұрын
@@Insighttecs thanks sir
@ramniwasgahlot7744
Жыл бұрын
How to find test result is ok ?
@vinodp8621
Жыл бұрын
How to identify fault after conduct the test
@JavedKhan-uz8ws
9 ай бұрын
Bro same question.. ??
@siva.k4579
Жыл бұрын
How much sqmm cable connect for primary & secondary & MCB,fues Rating please guide us fues
@Insighttecs
Жыл бұрын
you can choose the cable, fuse and MCB as per the reading of the short circuit test result in this series...
@Shivkumar-qp9wv
2 жыл бұрын
Sir in 20 mva star/ star 66 kv/ 11 kv connection will same as Delta / star
@badshahibrahim8475
2 жыл бұрын
Yes you can
@vinodbankar8942
Жыл бұрын
Test krne ke bad kaise smjna ki test value barabar hai ya galat???
@Insighttecs
Жыл бұрын
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching. we will definitely come to your point....
@waheedislam2989
Жыл бұрын
Purpose of this test..?.
@up_24king
Жыл бұрын
What is tap please tell me 😔⚡
@Insighttecs
Жыл бұрын
in EHV the transformer is comes with on load tep changer... where you can change secondry voltage of transformer by changing the tep position.
@up_24king
Жыл бұрын
@@Insighttecs thanks 🥰🤗
@mdnadeemhussainansari6770
2 жыл бұрын
This test is not suitable with fuse and small cable size
@anilkumarshah4523
Жыл бұрын
Very good sir Apko bahut bahut dhanyawad Apne bahut achha explain karte hai apki har video ko dekhta hu avr apke video se Sikh ke mai testing department me kam karta hu . Thanks Yadi hame kahi problem hoti hai apse discuss karna chahta hu please send me number...
@Insighttecs
Жыл бұрын
Thanks for watching 👍..we are glad to know that we have helped you to learn concepts..keep watching.
@SkulUK
Жыл бұрын
Sir, while preparing testing kit can we use MCB in the place of fuse? What should be the fuse and if mcb then current capacity to be used? Plz reply 🙏
@Insighttecs
Жыл бұрын
you can use ..... fuse make you confirm, for visually open and close.... so, during testing of faulty transformer you can be sure on the results.
Пікірлер: 41