Ma'am you're made it very lucid. Thank you & respect
@gargibasu5111
3 жыл бұрын
Thanks for liking
@user-ns3zh5cw2l
3 жыл бұрын
Thank you for making this video Ma'am. I'm a KTU student (Kerala)
@gargibasu5111
3 жыл бұрын
Glad it was helpful!
@indrajitroy2501
3 жыл бұрын
Thank you ma'am .... Much much helpfull to me 😊
@gargibasu5111
3 жыл бұрын
Keep watching
@mayasharma8335
5 ай бұрын
❤❤❤nice video mem thnk you so much❤
@gargibasu5111
5 ай бұрын
Most welcome . Keep watching!
@619r-zq2ck
11 ай бұрын
Very useful 🎉
@gargibasu5111
11 ай бұрын
Glad you think so!
@gobardhandey4970
Жыл бұрын
Very nice & helpful 👌👌 Thank you ma'am!!
@gargibasu5111
Жыл бұрын
Thanks for liking. Keep watching!
@Followthepage
2 жыл бұрын
Very help full and loved ur voice
@gargibasu5111
2 жыл бұрын
Thanks for watching.
@SoumCR3
3 жыл бұрын
Very nice Many many thanks for your helpful video
@gargibasu5111
3 жыл бұрын
Most welcome. Glad it has been helpful for you.
@sukhabeer007
3 жыл бұрын
excellent manner of study thanks mam.
@gargibasu5111
3 жыл бұрын
Thanks for liking
@arpitaarpi7015
Жыл бұрын
Thank you mam❤
@gargibasu5111
Жыл бұрын
Keep watching
@amitpandit745
7 ай бұрын
Great job 👍 mam 💯
@gargibasu5111
7 ай бұрын
Thanks a lot
@gargibasu5111
7 ай бұрын
Keep watching!
@apparenttradingsolutions3260
2 жыл бұрын
A 3,3 kV, 50 HZ, three-phase, star connected induction motor, with an output of 100 kW, has a synchronous speed of 500 r/min. The full-load slip is 1,8 % and the full load power factor is 0,85 lagging. The stator copper loss is 2,44 kW, the stator iron loss is 3,5 kW and the rotational losses are 1,2 kW.
@gargibasu5111
2 жыл бұрын
What should I calculate? I/p power=108.995kW, Armature current=22.434A, efficiency=91.75%
@motlatjokgare2024
Жыл бұрын
@gargibasu5111 may you kindly show how obtained the I/p (input power). I got 103054.99W
@mainakmukherjee_1067
3 жыл бұрын
Mam.. Mainak Mukherjee from JCGP here. Hope You remember... Thanks you for explanation !
@gargibasu5111
3 жыл бұрын
yes. What are you doing now?
@kommidicharithreddy0369
2 жыл бұрын
Thank u mam much much helpfull to me 😊
@gargibasu5111
2 жыл бұрын
Most welcome . Keep watching!
@AshenafiGobena
4 ай бұрын
good✌️
@gargibasu5111
3 ай бұрын
Thanks for liking
@samarpanghoshal10
3 жыл бұрын
Nicely explained 👍👍
@gargibasu5111
3 жыл бұрын
Keep watching
@sudha7524
3 жыл бұрын
Mam is slip and slip at full load are equal?? Or not??
@b40keerthanav10
Жыл бұрын
Calculate the speed in rpm of a 6-pole induction motor which has a slip of 6% at full load with a supply frequency of 50Hz. what will be the speed of a 4-pole alternator supplying the motor?
@gargibasu5111
Жыл бұрын
Synchronous speed of the motor, Ns2=120*50/6=1000rpm Motor's speed, Nr=(1-0.06)*1000=940rpm Speed of the alternator, Ns1=120*50/4=1500rpm
@Shahali2000
2 жыл бұрын
Please mam please measure the tension of each phase and slot by measuring the armature rotor of the induction motor. And please give a video of the cable size diagnosis
@gargibasu5111
2 жыл бұрын
I really could not understand what you did mean by 'measure the tension of each phase and slot by measuring the armature rotor of the induction motor.' About cable size diagnosis I shall try to be of help.
@MustafaAnooor
6 ай бұрын
mam, the speed at which the alternator runs, is it ns or nr or what's the kind of the speed, thanks very much
@gargibasu5111
6 ай бұрын
Induction motor and generator both run at speed Nr. Synchronous generator runs at speed Ns
@NaulaJacky
Жыл бұрын
hello madam but when your solving synchronous speed my madam told me the formula is Ns is equal f/p not 120f/p why
@gargibasu5111
Жыл бұрын
If Ns is measured in revolutions per second then Ns=2f/P If Ns is measured in revolutions per minute then Ns=120f/P
@brandonbrandizzlemartin
3 жыл бұрын
Good video miss
@gargibasu5111
3 жыл бұрын
Thank you. Hope this has been useful for you.
@Arshad-om6re
2 жыл бұрын
the reactance and standstill reactance of each phase of a three phase induction motor with star connected rotor are 0.06 which when connected to the rotor circuit will give a passout torque at one half of the full load speed .what is the power factor
@gargibasu5111
2 жыл бұрын
it seems there are some typos. The problem is not clear to me.
@intr_overtmind
Жыл бұрын
How to calculate slip at half load and no load?
@gargibasu5111
Жыл бұрын
At no load slip is nearly equals to zero. At half load slip is half of the full load slip/
@intr_overtmind
Жыл бұрын
So we just have devide by two?
@verhillovalakay5393
4 ай бұрын
Hi mis Gargi❤❤❤
@gargibasu5111
4 ай бұрын
Hello
@verhillovalakay5393
4 ай бұрын
@@gargibasu5111 your so cute mis gargi💋💋❤️❤️🤣
@sakshisaw7161
3 жыл бұрын
Problem no. 5 me kya kiye ho ap....s0= 1 ya 0.01 aur agar 1 hi lena hai to sfl= 3 hona chahiye 0.03 nahi
@gargibasu5111
3 жыл бұрын
per unit slip is 0.01 whereas percentage slip is 1. we can express slip in both ways. kindly go through your text book for the definition.
Пікірлер: 61