Dear sir Mai v 660mw me kam karta hun.aap lightup procedure par video banayye plz...
@BhagwanSRathore
Жыл бұрын
Mene already bna rakhi hai channel pr dekh skte hai
@nasimakhtar8657
Жыл бұрын
@@BhagwanSRathore sorry Sir Maine dekha nahin tha..
@nasimakhtar8657
Жыл бұрын
Dear Sir, Feed water ka flow kahan se lete hai..
@BhagwanSRathore
Жыл бұрын
@@nasimakhtar8657 flow measurement ka puch rhe ho kya plz explain your qsn
@nasimakhtar8657
Жыл бұрын
@@BhagwanSRathore yes sir
@AnuragKumar-cy5ll
Жыл бұрын
HRH temp is maintaining less than 540 (ie 530. -532) but RH metal temperature is going to excursion limit, what to do to reduce MTM? Will SOFA and CCOFA help in this?
@BhagwanSRathore
Жыл бұрын
Sofa ccofa affects sh and rh metal temp but if all the parameters of SH MS crh etc within the range then it can be due to scalling in rh tubes You can manage mtl temp by burner tilt position Shoot blowing Controlled CRH temp On a lower load the sofa can be minimised
@AnuragKumar-cy5ll
Жыл бұрын
If the opening of SOFA and CCOFA increase, then RH MTM increase or decrease?
@BhagwanSRathore
Жыл бұрын
Rh mtl temp will rise with more opening of sofa ducts ccofa doesn't effects significantly
Пікірлер: 25