I thought the activate check box is for waking up a very low battery that will trickle charge?
@duncanmartin8965
4 ай бұрын
Is there a way I increase the discharge of the battery as I am finding my house demand is quite high at some points and can see the inverter pinching power from the grid when I do not want it to
@rishibhayroo8434
11 ай бұрын
Do you perhaps know why my sunsynk inverter is using from grid instead of battery even though none of the system conditions have been met for grid use. Thank you Rishi
@immanuelh4637
10 ай бұрын
Please share how you resolved this
@RudiLouw
2 жыл бұрын
Hi. What is the function of the battery restart percentage? Is that the percentage where it stops supplying power and it reverts to grid to charge the bat?
@aneremmers
2 жыл бұрын
I would also like to know this.
@barrypickles6546
Жыл бұрын
My battery isn't communicating with the inverter so is just set up by parameters, unfortunatley the inverter cuts off the battery at 30 percent charge, is there a way to lower the discharge voltage cut off and if so can I do it from the menu or do I need an engineer? Also why stop a lithium charging or discharging at a % of charge? The battery is designed and controlled by an on board computer to be charged and discharged to a level.
@StephenTurley-gi3bz
Жыл бұрын
Thanks for the video How do you set up for batteries connected in parallel. I have 2 off Sunsynk 5kWh batteries connected to my Sunsynk 5kW inverter. What do you set the DC charging and discharging currents. I am using the BMS connected to each battery. As they connected in parallel do I double the individual recommended values. E.g. 50A x 2 so set to 100A DC.
@Bripromo
3 ай бұрын
Hi do i need to activate time of uses for my batteries to charge if I am off grid?
@keegangovender3312
8 ай бұрын
Can u please explain the 2nd Bar from the left "Out"....
@kirenpillay
3 жыл бұрын
I've added a Pylontech US3000C to my existing battery of same type. Do I double the charge/discharge settings, or is the setting for one adequate for both batteries?
@backboneenergy614
3 жыл бұрын
Hi Kiren. Please accept my apologies for this very late reply to your message, I am still new to this whole platform and need to get into the swing of things properly now. You can double up on your discharge current for the batteries but remember that the Sunsynk systems have maximum DC discharge currents, 185Ah for an 8kW machine and 115Ah for the 5kW , so you will not be able to exceed that anyway. As for the charge current, with Pylontech US3000C batteries I do not recommend going more than 70Ah on two or more batteries, just as a safety precaution. Thank you for watching our videos and please do not hesitate to ask more questions, now that I'm getting the hang of this. 😅 Regards C.
@kirenpillay
3 жыл бұрын
@@backboneenergy614 Thanks for the info. Will check my settings!
@JeGo9
Күн бұрын
@@backboneenergy614 hi! do you also need to double the "Batt Capactity" if you have 2 x 100Ah batteries? thank you!
@tygerhillsguesthouse2932
10 ай бұрын
I have a 40/32 Freedom Won battery system and 2x12 Kw Sunsynk Hybrid Inverters. The 40kWh battery has no earth on it, as the installer don't know how to install it. How and where do you earth a big battery such as as a 40/32?
@dama054
Жыл бұрын
So can you use a sunsynk inverter with lithium battery s without BMS connection
@markevans4832
Жыл бұрын
Help please as just had a Sunsynk system installed. Should the system automatically export to the grid any surplus once batteries are at 100%. Mine seems to show on app that no solar is being produced when batteries are full until a load is put on the house using the battery.Solar production then shows again with none having been exported during the time when batteries were full. I am a confused newbie so please help.
@DACatface
Жыл бұрын
I am commenting because I had mine installed today also and would love to know this as well. I'd like it to export only when battery full
@JohnMoolman
Жыл бұрын
Hi Is it possible to prioritize battery charge from PV array only. My elec bill has doubled assuming this is due to grid being used to charge batteries.
@AlbertCloete
Жыл бұрын
Yes, you can set it to charge only from solar. Check in system settings in the first tab. There are checkboxes to select on which times of day it should use solar and/or grid to charge. So you can set it to only charge off grid during the day, but allow it to use grid energy at night if the battery dips below a certain percentage. This should also allow your battery to power your essential and non-essential loads at night, up to a point. You can save a lot of electricity costs this way.
@rbee3936
Жыл бұрын
You may be able to set 'shutdown' to 20%, but I tried setting mine to 0%, but it still shuts down at 10% - this seems to be the minimum, so the batteries don't have a depth of discharge being 100% after all (as advertised on the spec sheet), but just 90%, wasting 10% of the battery's charge.
@vishaymohan3030
Жыл бұрын
Is the battery capacity the total battery bank capacity ?
@milan1p
Жыл бұрын
Thanks for the video. How do I find the Absorption and Float voltages for my battery? The data sheet says the cut off voltage is 57.4v is that the absorption voltage? What would be the float? My battery has a BMS that is communicating with the inverter so are these settings required?
@rbee3936
11 ай бұрын
Why doesn't 'shutdown' work at 0%. It keeps shutting down at 10%, so I basically only have an 18KWh battery not 20KWh as I can't access the last 2KWh...
@barrymaccoll7334
2 жыл бұрын
On the second battery tab there is an equalisation days and hours. Is this setting for how many days between equalisation charge? And for how long the equalisation charge should be?
@rolandtruter6219
3 жыл бұрын
Hi, with the litium type selected do I need to have battery communication with bms. I know that it is recommended but if I dont have a lithium battery that is compatible with sunsynk will this still work in this battery mode if i set the patameters manually?
@PaulS-nw1cv
Жыл бұрын
Thanks for the video, can you limit the battery SolarPV charge to 80% max? Ie stop charging from PV when SOC = 80%?
@chickenclips
Жыл бұрын
Yes you can
@heisenberg6442
8 күн бұрын
Use the timer settings.
@mikelaurie3850
2 жыл бұрын
Will sunsynk do comms with shoto?
@derronasimmonds6468
2 жыл бұрын
do you have a manual for skytrak inverter
@arccon82
2 жыл бұрын
Every time my battery drops down to 20% I would like to charge it up to 60% from the grid. . How do I do that?
@backboneenergy614
2 жыл бұрын
Hi Karol G. If you use the timer function you can set the battery to charge to the set SOC during whatever time as long as you have grid ticked. So in system mode, select "use timer" set the SOC to 60% at say 1 to 5am and select grid and that will then do as you want. I know this is a rather common request in the UK with the different tariff times.
@arccon82
2 жыл бұрын
@@backboneenergy614 thats the problem. I do not want to use timer. I do not want to top up the battery in advance, in the Night, as when the day is shiny I want to use solars to top up the battery, so topping up battery from the grid at 5am makes no sense. But on a rainy winter day when solar is not enough and I use more than I charge I would like to be able to top up the battery when it drops to 20%. So basically at any time during the day when battery drops to 20% use the grid to top up. But only when it drops to 20% if its more it should run as normal.
@mprelectrical
Жыл бұрын
Nice nails man 🤣
@Thetruthshallsetyoufree-
3 ай бұрын
😂
@starweldwork3025
Жыл бұрын
sir please help me i am an elctriction i am doing sunsynk inverter installation i don't know much english so sir please help me speak simple english send me video plz thank you
@mosesmushata5755
2 жыл бұрын
I installed 12KVA,3phase sunsynk inverter but it is charging using solar panels only ,AC is just indicating an arrow from the grid and disappeared
@rbee3936
Жыл бұрын
You completely skipped over the 'protocol' setting...