Thank you Benrie. Just the information that I was looking for. That is the only piece of the puzzle that I was still looking for. I am off-grid with 40kW of battery (28kW effective ). I have changed my 3kW geyser element to a 2kW element and it is astounding how much 'smoother' it is on the battery. Geyser on timer but the wife has to shower at 02H30, and I need to shower at 06H00. Although a kW is a kW, it seems to have much less drain on the battery, and not so much of a spike in the load. Please keep posting anything new that you find out.
@Butabru
11 ай бұрын
Thanks so much Benrie ! The clearest answer I have seen, I've been looking at many vids, forums etc, could not clearly grasp the relationship between the % Value, and whether Grid was ticked or not. You put it very well, and then proved it with your switching geyser .... You're a star *****
@benriefourie115
11 ай бұрын
I appreciate it 🙏
@CrimsonAlchemist
3 ай бұрын
Thank you so muuch from Myanmar. Noone could answer my questions exept your video
@GeorgeSmooth
4 ай бұрын
Hi Benrie, really appreciated this video you made. Was so simple to understand. Thank you.
@gerritdevos4707
Жыл бұрын
Dankie Bernie. Goeie video.
@immanuelh4637
5 ай бұрын
Thank so much. Others keep preaching but don’t say nothing
@nickidewet7711
10 ай бұрын
Ek verstaan die spesifieke item wat jy verander het, maar kan jy asb verduidelik vir elke lyn van bo tot onder hoe die inverter sal werk deur al die verskillende tye?
@stephhaumann327
11 ай бұрын
Hi, a novice here, fiddling with his own system. Awesome vids, Thankyou... I have a 5kw Sunsynk inverter with battery and solar panels. At the moment my Geyser is pulling from the battery and the pv when it comes on. I want to set it so that the geyser only uses pv and grid power, but no battery. Where would I go to set that. And then 2nd question, if possible, Can I set it so that when the geyser comes on, and SOC is above certain %, that it first uses battery until , for instance 80%, and then use grid from there on? Looking forward to your reply.
@benriefourie115
11 ай бұрын
Hi. So there 2x questions here. 1st, I will play a bit and see, but need some info. Is your geyser running on a timer? On what side if the inverter is the geyser connected? If you have a timer on the geyser, you could use the timer function, like on my video, for the set time the geyser runs, but not select the grid tickmark. Meaning it will use PV and Eskom to supply the load and not use the battery for that time. 2nd question on the battery usage to a certain %. I would say yes, but it wont be easy. You can control you Sunsynk with Homeassistant, but you need to use Nodered running trough the modbus port. That way you can switch anything on or off with smart switchs on any condition ( like battery state of charge) , you can change inverter timers and charging/ discharging. But they is very complicated. I havent done it. When I have the time some day I will look into it for myself. But for now, I dont have an easy answer. Or perhaps if you have a timer on geyser, set your inverter timer for that time to 80%, so it will use the battery down to 80% and then pull Eskom to keep it from not going below 80%. You can ply with "prioritize load" but that would be to permanent and you wil use Eskom.
@stephhaumann327
11 ай бұрын
@@benriefourie115 Dankie vir die reply Bernie. Ek dink ek sal so bietjie speel. Die geyser is op 'n timer, ja. Ek sal dalk jou eerste voorstel gebruik. Die Time zone net verander vir hoe lank die geyser aan is, en die grid merk verweider. Dit sal darm help vir die tye wat die geyser geskeduleer is, maar nie as mens dit op 'n ander tyd wil aansit nie. Ek het gedink daar is dalk 'n manier om die non essentials net van PV en grid te laat run. BV as die son skyn en panele wek genoeg op, kan die geyser net PV gebruik, en indien dit te min is net die res by grid kry.
@robertguest7808
11 ай бұрын
Is there a reason why the gen is all ticked .
@benriefourie115
11 ай бұрын
@@robertguest7808 hi, no reason at all for me. It was just like that from the factory.
@jarobertsrsa007
Жыл бұрын
Thanks for this. How many watts is your geyser? I really want to put the geyser on the ‘ups’ load.
@benriefourie115
Жыл бұрын
Standard 3kW element on the geyser. I have only once rund into an overload. My bill went from R1300 /month to R50 😁
@jarobertsrsa007
Жыл бұрын
@@benriefourie115 wow. That’s amazing. And to confirm it’s on the load side right?
@benriefourie115
Жыл бұрын
@Jody Anthony Roberts correct. Everything powered through the inverter. I, however, have and switch over to throw the stove and geyser to the utility side should I want to use all the equipment on the stove together ( that's about 13kW and has never happened) Also, if it's on the utility side, I dont have power to the stove and geyser in loadshedding, nullifying the reason for going solar. So, thus far, everything in the house runs 100% through the inverter.
@jarobertsrsa007
Жыл бұрын
A run through of your system setup would be a great video. What battery, the switch over. But thanks for sharing your info anyway. Who did your wiring for you if you don’t mind sharing?
@synthwave7
Жыл бұрын
@@benriefourie115 The only issue people are reporting with running your geyser on the inverter is - the battery life (cycles) drops tremendously - you are therefore shortening the lifespan of your batteries severely.
@jarobertsrsa007
Жыл бұрын
We video request please. Wiring setup and switchover please
@snyman9520
Жыл бұрын
What happens if the grid is down when you reach the battery percentage - will it drain below the set percentage or will the inverter switch off to keep battery at set percentage?
@pantoffelslippers
Жыл бұрын
It drains below down to the inverter shutdown percentage. It’s usually 10% or 15% by default and is configurable on another screen.
@synthwave7
Жыл бұрын
Dankie - hierdie menus is baie confusing.
@rohanndutoit4544
11 ай бұрын
I have connected my generator to my inverter and set it to pick up at 40% and shut off at 95%. The generator should push 3.5kW, but it is only pushing power towards the house and not charging the battery at all. Is there a setting I'm missing somewhere?
@benriefourie115
11 ай бұрын
Hi. Yes.l, it might be one of 2x things. What is your current load? If your genie is supplying 3.5kW but your load is 3.5kW or more, there is nothing left to go to the battery. But setting wise, get out of this screen and go into your Battery settings screen. Make sure Gen is also selected there and that the charge current is not set to 0Amps? Let me know if it works.
@rohanndutoit4544
11 ай бұрын
@@benriefourie115 Hi Benrie ja the current load is only 243W and it all being supplied to the house from the generator. The battery is being charged (slowly, very rainy day) by the panels, but nothing from the generator sadly
@FourieChristo
2 ай бұрын
ek het 19 panele 450w, en n 8 kw sunsynk inverter ek is besig om myself deur die ore te spyker want ek gebruik nogsteeds R2000pm se krag ek doen iets verkeerd ek sal beste settings vir somer en winter wil he om geld te spaar
@benriefourie115
2 ай бұрын
Hi Mr Fourie. Ek wil net noem dat ek glad nie n installer of seller is nie. MAAR, ek like die goed baie. Ek het al familie gehelp met hulle settings en ons kan verbeterings maak. Stuur my dalk jou nommer, dan whatsapp ek jou en ons kan bietjie speel met jou settings.
@SathishSrinivasan-xm2xl
Жыл бұрын
what does the power - 8000 refers to? Also lets say if my load is 8kW and my battery set discharge current is 4kW, will it take remaining from the Grid in this case?
@benriefourie115
Жыл бұрын
It should yes(when no PV is available)👍
@benriefourie115
Жыл бұрын
8000w is the power the inverter is allowed to take from the battery.
@etiennelr
Жыл бұрын
Is there a way to cap the maximum charge of the battery to say 90% so extend the life of the battery?
@benriefourie115
Жыл бұрын
Unfortunately not that I know off. Perhaps put the battery in "manual charge mode"? But I don't like that so much as you SOC isn't 100% accurate sometimes. But I guess its worth a shot?
@bedofromkokstad9034
10 күн бұрын
Sjoe, ek het nou lank gesoek vir hierdie inligting! So vies.... Na installasie kom my krag rekening nie af nie. 8kva inverter, 2 x 5kw Li batterye en 16 paneled en klein ou huisie met net myself.... Ek behoort alles van sonkrag te kan hardloop. Gaan hierdie nou toepas. Hoe kan mens jou kontak vir advies Benrie?
@benriefourie115
5 күн бұрын
Hi. Los jou nommer hier dan sal ek jou whatsapp. Ek help graag.
@bedofromkokstad9034
5 күн бұрын
Dankie Benrie, het reggekom. Ek wys nou vir ander mense hoe dit werk...! 😊
Пікірлер: 38