This was an exact replacement for the old one that lasted about 10 years. kzitem.infoUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).
@IpodNutz
5 жыл бұрын
How about the exhaust pipes? No mention on that.
@j.feldmander1956
6 жыл бұрын
The proper plumbing kit for flushing the scale build up out of the heat exchanger is not shown or even discussed in this video. It all seems professional except for that one major oversight.
@reedrobb
5 жыл бұрын
All that beautiful work, love the safety gear, but what about escutcheons? They would clean up the bad drywall around the pipe through the wall.
@carlysheff
3 жыл бұрын
So helpful and clear. Thank you so much!
@exceleratorjoshua
5 жыл бұрын
2 gas shut off valves that close to each other are not needed. That check valve shown better be a spring loaded check valve, because if it's a typical swing check valve it's not installed correctly. Swing check valves can only be installed horizontally not vertically. Only problem I see so far is the lack of a shut off valve on the hot side. Reason being you won't have to shut down the whole building water supply if you have one shut off valve on each line. It also helps to do service or swap the unit out easier and quicker, no need to pull the TPR in order to drain the system or open up faucets and turn the whole building water supply off.
@dvcrocco
4 жыл бұрын
I have never seen a check valve on an installation like that. Also, it is a swing check and will always be open.
@Hever73
5 жыл бұрын
No flashing kit! not exhaust vent pipe?
@paddypointhound1688
4 жыл бұрын
my friend has a tankless heater,it has a tee in the cold water line going in the unit,and runs to the cold water knob in her shower,is this correct?..or does the cold water have to be seperate from the line going into the unit?
@socksincrocks4421
4 жыл бұрын
I thought a flexible gas line is not permissible. It must be hard piped, right?
@dvcrocco
4 жыл бұрын
Depends on the local utility. NFG code allows a properly sized flexible connector. Still need a sediment trap, however.
@2u263
3 жыл бұрын
Could use a non condensing vent installation demonstration for Non Condensing Takagi110U-I
@rebelman1776
5 жыл бұрын
About time I saw someone install a sediment trap the right way
@michaelnelson2951
5 жыл бұрын
Thanks nice overview, but, what about air supply and exhausting?
@chefbambu9382
4 жыл бұрын
Where do I find the water pipe (H&C) standards? Can PVC be used? what's referred and why? Thanks.
@rhdtv2002
4 жыл бұрын
I think you can use CPVC
@dvcrocco
4 жыл бұрын
PEX is commonly used.
@jimwilson8509
4 жыл бұрын
NOTHING MENTIONED about Exhaust system , type pipe, requirements
@jdubya54
5 жыл бұрын
Awesome video. What about the flue
@sorghumcrow7289
5 жыл бұрын
It's an electric model. You might as well look for a tailpipe on a Tesla.
@titan_3634
5 жыл бұрын
@@sorghumcrow7289 then Why the gas feed line??? lol
@matuajohnson2060
5 жыл бұрын
On the hot side he went from metal to Copper that will cause electrolysis
@dvcrocco
4 жыл бұрын
The tank connection is brass, which is dielectric.
@davenelson1638
5 жыл бұрын
Lol. You soldered pro press fittings. Thats funny. Maybe I can make videos too. How did the melted rubber from the o-rings work out in the heat exchanger
@Authoratah
5 жыл бұрын
should've installed special tank-less service valves
@RunE076
3 жыл бұрын
They are called ISOLATION VALVES
@D_Snapp_Garage
5 жыл бұрын
Does propane also require a drain leg?
@dvcrocco
4 жыл бұрын
Propane is even dirtier than natural gas. I would use one.
@joseartiaga3048
4 жыл бұрын
That prv drain should be going outside
@sandman70131
5 жыл бұрын
Is he soldering a propress elbow?
@BC-sk3bp
4 жыл бұрын
No it's a yorkshire fitting. Oh yeah you can sweat a press fitting..🤣 But you gonna burn the rubber. 🤣
@vinjulieann1
4 жыл бұрын
Plumbers charge way too much to install these or water heaters - on a $329 electric water heater they want to charge $1700 to replace it.