Awesome man, proven that this method is probably as good as it gets, I’m new at these and your video was indispensable, thanks
@VintageEngineRepairs
2 жыл бұрын
Pleased to hear it mate :) lots of people discredit them because they haven’t put the time in to get use to them, but when you do, they’ll be as accurate if not more so than a dial bore gauge which typically read to 0.01mm where as this set up reads to 0.001!
@KensSmallEngineRepair
2 жыл бұрын
I love the lingo across the Pond, Gudgeon Pin? We say Piston Pin or Wrist Pin. I’ll take a dial bore any day but there are errors using a micrometer to set up a dial bore versus a calibrated ring gage or dial bore setting fixture. Good vid Mate!
@VintageEngineRepairs
2 жыл бұрын
Well said mate! Both require accuracy and attention to detail. Thanks for watching and sharing your experience!
@pierresgarage2687
3 жыл бұрын
Your method is a little slower than what I do, though, the results are really excellent, good point mentionning the use of good quality gauges, I know by experience that cheap gauges aren't good for anything. All in all, you understand quite well the principles of the whole process...
@ikbendusan
Жыл бұрын
i will be buying telescoping gauges based off of this video, thanks!
@VintageEngineRepairs
Жыл бұрын
My pleasure :)
@GraphicManInnovations
2 жыл бұрын
by far the best demonstration available to date, however u forgot to cover the mic markings, now some might tell u were cheating using them :)
@GraphicManInnovations
2 жыл бұрын
@@VintageEngineRepairs correct:)
@23davidian96
Жыл бұрын
2 things I don't fully understand: 1. How do you find centre so easily? Surely the gauge doesn't want to be perpendicular to the sides of the bore? The springs want to push out and skew the gauge? 2. Not quite sure what you mean when you pull back when tightening the nut at the bottom?
@VintageEngineRepairs
Жыл бұрын
It will automatically search for the widest point. Pivoting the gauge in the bore encourages this. When I say pull back when tightening the nut it helps maintain friction between the gauge and bore and stops it slipping off and affecting the accuracy of your measurement. It’s just light pressure.
@nikegrekna
7 ай бұрын
베어링 내부 공차는 - 값으로 만들어 지는데, +0.003 은 잘못된 측정입니다.
@VintageEngineRepairs
7 ай бұрын
Hey :) I’m sorry I don’t understand
@horseshoe182
2 жыл бұрын
but a dial bore process is a one step .
@VintageEngineRepairs
2 жыл бұрын
Not in setup and often only gives you to the .01 of a millimetre.
@berniemcgee2964
Күн бұрын
I use pretty much the same method as you and I find if I invest the time and effort as you have done they are indeed very accurate. Once the gauge is set in the bore I take the time to properly set the mic as you do. Having done that, if I need to be very precise, I return the gauge to the bore and 'feel' it in the bore then check the 'feel' back in the mic without changing the mic setting. If the feel is the same on both the I’m confident I have a accurate bore size. I’ve checked this method on occasion with slip gauges held in an internal bore holder and found it to be within a couple of microns every time.
@VintageEngineRepairs
Күн бұрын
Yep well done, same here. It takes skill and time, but it’s well within the accuracy of any dial bore gauge measurement!
Пікірлер: 17