Hello Peepaw,, I always like to stop the shop to see what you’re working on. I appreciate how thorough and patient you are, it helps me to grasp what you are sharing. I look forward to the next time, take care. Safety always!
@electronicscaos
4 жыл бұрын
Hello Mr. PeePaw, how are you? This Lenze equipment was so good and so flexible, I'm sad they dropped the production to this trash they are selling now. In the shop we are specialists in both Lenze (93xx) and Baumuller old stuff, and I already saw some of this new stuff from Lenze destroyed, because of this new bus concept they are using now. The bus don't take the overload of a shorted IGBT module very well, normally you get both the bus and the power board destroyed, leaving the only possible option of buying new stuff. Programmed Obsolescence? We can't tell... But is sad to see that inside it's basically the same electronics as the 93xx, packed in the wrong way. By the way, I've some good news! We are going to represent a big machinery manufacturer, that have lots of KEB equipments around our country. We already fixed 3 machines, and both sides are getting excited on how well it is turning. I believe we are going to make a good deal this time haha... If you need advice about Lenze 93xx, I'm glad to help you, just email anytime, my friend. Cheers buddy 🍻
@PeepawMcDonald
4 жыл бұрын
Hello Mr. Riggs, great to hear from you again. I am very happy that your repair business is going great. There ain't to many folks can repair these things. I have not seen the new Lenze equipment. From what you describe, I don''t think I want to. HaHa... Thanks for being there:)
@skypeople2
3 жыл бұрын
Hi Mr Riggs i suppose you're well verse with Lenze 9325, may I ask how to reset internal controller inhibit error without the XT keypad?
@electronicscaos
3 жыл бұрын
@@skypeople2 hi Thomas. If the internal inhibit error that you are saying is the same I'm thinking, you should correct by applying 24V to a connector. Please, specify the exact error so I can give you the right direction.
@skypeople2
3 жыл бұрын
@@electronicscaos Hi sir, the machine error code is C0183/122 "controller inhibited internally", does this mean connector X5/28 is supplied internally or the 24V should be supplied to connector X5/28 externally? is it possible to clear this error by setting connector X5/E5 "trip reset" to high? please enlighten me thank you
@electronicscaos
3 жыл бұрын
@@skypeople2 I believe there is a connector X11 in your drive. If that is the case, you must provide 24V to this connector (according to manual) to disable the internal safety inhibitor circuit. Let me now if it worked, and ask me if I can offer further help.
@LalBahadur-ex8ds
Жыл бұрын
i have to copy past how can i do
@dareknazwisko
2 ай бұрын
Tak bez resolvera? Nie ma błędu SD2 ?
@zlatkomladenovic
3 жыл бұрын
Greetings I have few of thous inverters (5 to be more precise) and same number of encoders. It is comunicate on profibus dp... my question is can i use that inverters and make CNC mill?
@teejayelectronic4474
3 жыл бұрын
need parameters settings before run the any motor with lenze drive please share setting which you using to test drive on bench with motor
@kaatnikaatni9012
4 жыл бұрын
Great video Peepaw. God bless.
@alibinnasiralharthy2911
4 жыл бұрын
Sir Peepaw i want ask you about Allen Bradley sensor less vector drive, have u ever worked on that? Please
@cncservice1532
4 жыл бұрын
Nice.....did you have something for testing siemens sie20031 and sie20034.... regards from Croatia
@qaisarabbasi2219
3 жыл бұрын
Hello sir am repairing vfd sir am facing problum with lanze E94AM highling drive runing 10mint after that disply showing fault heatsink cooling fan fault i found bsp pnp transister replce with same number now same fault thanks
@VictorHernandez-pr7lb
3 жыл бұрын
Hi Mr. McDonald I have a LENZE drive EVS9326-EVS004 model and I need test it using LENZE motor MCS09D41 type with encoder feedback. Can you help us to definy parameters for test unit ? Note: I am using Global Drive Control software
@manuelrengifo4507
3 жыл бұрын
Hello dear i hope you are well. Please help me if possible to find new or used lenze emf9373db programming interface and lenze pc software OS LOADER V31 . This to can switch from Cam Profile V81 firmware to Servo Inverter into a lenze 9300 22kw power unit . Thanks
@джахбаралиев-з7ф
3 жыл бұрын
how can you learn this
@al-amintusher4280
Жыл бұрын
Hi Sir.
@jezielalmeida6619
4 жыл бұрын
Mais uma vídeo aula
@عبدالعزيزالطلاس-ل5ج
2 ай бұрын
😊😊
@pramodgulve7021
4 жыл бұрын
Nice video 👍
@engkamran5817
4 жыл бұрын
drive not running ... i think there is some parameter settings ? please share the correct setting for parameters ? eng.kamran.oman@gmail.com
@engkamran5817
4 жыл бұрын
need parameters settings before run the any motor with lenze drive please share setting which you using to test drive on bench with motor
Пікірлер: 27