- 15kwh with say 80% dod it will be like 12.5kwh, if u use a 1HP inverter AC at 750 - 800watts for the whole night. That will be roughly 16hrs if u run just the AC. This battery i believe is 6000watts normal running and 8000watts surge for some seconds, which means u can use up to 6000watts continuously without any problem. Pls get ur facts right. -
@omotoshogoodness
12 күн бұрын
We literally have this battery at home, the 17.5kwh system…once we consume anything more than 2500w, it start vibrating but we don’t mind it though.
@gqstyle74
11 күн бұрын
@@omotoshogoodness I have heard this from another installer called @solargod he is really good.
@omotoshogoodness
12 күн бұрын
If you’ll be using a hybrid inverter, there’s no way you’ll use a 3.5kva for 15kwh battery…it’s inbuilt controller will not be able to handle all the panels
@tangodigitalsystems
9 күн бұрын
'was expecting him to talk about the DOD.
@LexionKing
9 күн бұрын
Do your research well before coming to Public spaces. I Doubt he knows what a Battery C-Rate means. Most Lithium batteries have ratings of 1C, which means you can safely discharge the entire battery capacity within 1 hour, as long as your wire gauge sizes are right for the highest amount of current you want to draw. So, saying you can only use a 3.5kva inverter for a 15Kwh battery with 1C C Rate is absolute Bullocks. Stop passing out wrong info. Read and research more to get better @ your Job.
@enahorookhamafe2710
16 күн бұрын
I frankly don't understand whst hes saying about using 3.5kv on 10kwh or 15kwh battery. First, 15kwh is equivalent to at least 6 tubular batteries. That battery can carry any size of AC upto 3hp. It's the run time that's the issue. I have never heard battery vibrating oooo.
@chukwuemekamadubukoe.2179
15 күн бұрын
E shock me too oh😂. I've never heard that anywhere
@raymondikediuwa2250
15 күн бұрын
His explanation of the inverter size to the battery is wrong, the inverter can take any load within its rated range and drain the battery much faster, and the cables between the inverter and battery may develop temperature if it's not properly sized, the issue of vibration is what I don't understand.
@omotoshogoodness
12 күн бұрын
Fr it shouldn’t, but Felicity does actually
@onyeneato3890
7 күн бұрын
3hp for 15kwh battery shukkk😮😮
@SUPREMEJUSTICEAIWANFO
7 күн бұрын
12v220Ah is 2640 Watt hours 12v200Ah is 2400 Watt hours
@GTdontDOthat
16 күн бұрын
5 tubular battery is not up to 15kwh 220*5*12 not up to 15
@tayogbadebo23
Күн бұрын
This guy doesn’t know what he is talking about, God help us with Nigerian so called engineers
@mrace5904
16 күн бұрын
Lol 200ah is equivalent to 2.2kwh
@future--tv
15 күн бұрын
This Man doesn't know anything point of correction is the inverter that does the work all you need is to have 5kva or 10 kva inverter
@godsonoroku1134
7 күн бұрын
This guy is talking nonsense
@oyefisayowole4042
14 күн бұрын
Highly disappointed! This installer dey yarn dust; technical knowledge is lacking.