That 3" combination serving that toilet should have been a 3" long sweep. Before that combination, you could have put a 3" wye to serve your sink. That would have been your vent to. Then make sure that you are not close than 15" center to center of your fixtures.
@SRTPCC
2 жыл бұрын
That's a 4" long sweep to the toilet, hard to see. But I like the Y idea. I like the comments on how to make it better
@chiefeagle5882
Ай бұрын
that vent is required to be above the flood level of the fixture! It will leak in the future.
@sonnynguyen8012
Жыл бұрын
Thank you so much for useful video ❤
@SRTPCC
Жыл бұрын
Glad it was helpful!
@sonnynguyen8012
Жыл бұрын
@@SRTPCC ❤️
@randydemars3734
5 күн бұрын
Cutting off a sewer pipe just above his canned good storage! Not eating at his house!
@SRTPCC
5 күн бұрын
Hahahaha
@happysunflower4586
2 жыл бұрын
Thank you! My vent is letting moisture come into the cabinet underneath my kitchen sink. I think I will replace the vent and see if that helps. I have a feeling the vent might be all in this faulty???? Any suggestions?
@SRTPCC
2 жыл бұрын
I believe they are open to air by design. From what I know water is what it won't let out.
@user-fg8ns5ud9l
Жыл бұрын
What did you put on (like a cap) at the last step right before the flush test?
@SRTPCC
Жыл бұрын
That is a threaded clean out plug from where the vent was originally
@gildardomerancia5818
8 ай бұрын
Hey buddy just keep both vents it will probably work better .
@SRTPCC
8 ай бұрын
Truth
@user-nn1lo8sj9y
2 ай бұрын
bad bad jobber !!!!!!!
@SRTPCC
2 ай бұрын
IKR
@bwrick21
Жыл бұрын
Can you hook up a studar for all bathrrom fixtures?
@SRTPCC
Жыл бұрын
I'm no plumber but I think one does the trunk line for all three fixtures, Toilet/Sink/ & shower
@ABOULBARAHEM
Жыл бұрын
What if you install the vent on the 100mm pipe not the 50mm does it still do the same work ?
@SRTPCC
Жыл бұрын
I believe that would be the correct way between the toilet & the sewer
@randolphrussell1751
2 жыл бұрын
Does not look like this would pass a plumbing inspection. Never thought it was a smart idea to put a Studor vent BELOW the fixture it was supposed to vent. It the under sink Studor was installed correctly then a 2" vent would be enough to vent the crapper. Total distance from the centerline of the flange doesn't look to be over 5 feet or so. Please follow up in the future when you have a sewer line blockage and the effluent backs up to your vent.
@brianczuhai8909
2 жыл бұрын
Potential clogs is the reason the air admittance valve vent needs to be above the top water level of a fixture. It's also the problem using them UNDER sinks. The one way valve on them may fail.
@MarkMinistries
Жыл бұрын
How big is that Oatey vent 3 inch or 4 inch?
@SRTPCC
Жыл бұрын
It fits 1 1/2" or 2" both
@amandawallace105
Жыл бұрын
My kids restroom toilet is doing the same thing and has a nasty smell no matter how much a clean it. Is that a sign it needs to be vented?
@SRTPCC
Жыл бұрын
If there's a smell I'm thinking there's already a air leak somewhere that needs to be tracked down. I'm not certain a vent install would fix your prob but there's way smarter ppl on here than me on this, sorry
@amandawallace105
Жыл бұрын
@@SRTPCC the toilet does move around, could it be the wax ring ?
@SRTPCC
Жыл бұрын
@@amandawallace105 Yes Ma'am
@SRTPCC
Жыл бұрын
Check for toys down there also with kids maybe
@amandawallace105
Жыл бұрын
@@SRTPCC 😆🤣 my kids are teenagers , I really hope no toys are in the drain
@georgetsetsakos6088
2 жыл бұрын
"It's a little pasty!" That's legit. lol
@haitong7305
2 жыл бұрын
Can you put the air vent side way or it have to be up right?
@SRTPCC
2 жыл бұрын
It needs to be up for valve to work right
@steveduranko4911
2 жыл бұрын
That toilet is wet vented thru the lavatory and a toilet can be unlimited distance from a vent because it’s a self siphoning fixture.
@SRTPCC
2 жыл бұрын
Right on
@brianczuhai8909
2 жыл бұрын
That's because the toilet bowl keeps filling after the flush and reseals the trap. However, if vented properly you won't get that glug, glug, glug sound of air being sucked into the bowl right after the flush. Since there's a vacuum pulling the air through the trap in the bowl, it also pulls back the flush going down the pipe.
@arlenmargolin4868
2 жыл бұрын
It looks like you went way down in pipe size you need to keep a large vent the same size otherwise I think it will have that problem
@SRTPCC
2 жыл бұрын
Still working great
@sarahmangone7785
Жыл бұрын
Also, it's installed too low. After watching it fully, I see you moved it up.
@elmono3939
Жыл бұрын
There is so much wrong with plumbing in this video that I don't know where to begin. To everybody who is watching this - please do not follow this DYI's instructions. Consider yourself warned. Thank you
@vicschauberger2737
8 ай бұрын
Agree. Do not follow this demonstration .
@4doorsmorewhores674
7 ай бұрын
lol im fixing to do it lol that lower vent he is putting in is only a problem if there is ever a clog right?
@mouuseygb
7 ай бұрын
@@4doorsmorewhores674 Technically yes. But do you want to chance that?
@vicschauberger2737
8 ай бұрын
This is wrong . You need a 3"x 2" wye before and within the code distance of the 3" toilet 90 or a 3" x 2" side outlet 90 at your toilet . The the 2" of either of those configurations runs to your Lavy ( sink ) . The in-line vent should be 6" above the flood level rim of your lavy to prevent debris from clogging your vent in case of a drainaige back up . . Now , with what you did , the sink also has no vent . This is supposed to be a wet vent configuration . Where the lavy can vent the toilet . It's best to run the 1 -1/2" lavy vent thru the roof . That's just the beginning of what's wrong with this . Sorry .
@sparky3869
2 жыл бұрын
The plumbing is done wrong. If it were pipe correctly, it would not have been a problem.
@SRTPCC
2 жыл бұрын
Seems to work good but yes I just pieced it tog myself
Пікірлер: 51