Very cool video, interesting to see there are modules to make manual generators automatic, also the company gave itself a very good reputation by admitting to their error and helping you throughout the installation process
@rolandmcphail5060
Жыл бұрын
great feature that timing delays can be configured and adapted. those types of delays are essential in my everyday work in industrial controls.
@cheetawolf
Жыл бұрын
I just bought one of these portable generators today, this video will be incredible useful in unlocking its full potential, thanks!
@ForTheBirbs
Жыл бұрын
Wago connectors work fantastically well. Have been used in Europe for many years. And yes they need to be weather protected
@ForTheBirbs
Жыл бұрын
So satisfying when a project works. Well done!
@ForTheBirbs
Жыл бұрын
Another great video. A couple of suggestions from years of electronics and electrical work 😅 - get yourself a ratchet terminal crimper as you get consistent pressure and more reliable. Main one is don't use those horrible fake scotchlock blue wire crimps. They're very unreliable. You can get gel filled ones that work well, or even better, solder and heatshrink the wires.
@ChrisTopher284765490
Жыл бұрын
Best part was “ You Look Pretty Helpful “ Hahah Classic !
@captainchris2016
Жыл бұрын
I would like to have this kind of setup in my house, probably when I have my own house.
@ForTheBirbs
Жыл бұрын
One other thing is that the relay coil should have a diode like a 1N4007 across it to suppress the big spikes when power removed. Just got to make sure it is "pointed" negative to positive
@suchcone
Жыл бұрын
Neat upgrade! Im a big fan of using DIN rail as everything can just mount on to it, relays and connector blocks included, but plastic boxes are so convenient and rugged. Im guessing you could add a timer to the AC input so the grid power needs to be on for a while before the generator turns off?
@nics-systems-electric
Жыл бұрын
I did that in a update to the controller itself
@Friendlytaco
Жыл бұрын
Ayla is a certified supervisor so she was there to make sure that you were installing it properly
@nics-systems-electric
Жыл бұрын
That's right
@Friendlytaco
Жыл бұрын
@@nics-systems-electric lol
@N1tr0_fox
Жыл бұрын
Verry cool video been waiting it for ages keep up the work nic!
@FireAlarmNZ
Жыл бұрын
Amazing video! I can totally relate to the initial challenges of automating a generator. I wish I had filmed the process of connecting mine, but it can be quite time-consuming to juggle filming and figuring out the installation simultaneously. It's truly refreshing to see someone document the process, especially considering the lack of information available on KZitem. By any chance, do you know if there's a way to incorporate a cooldown period to ensure that the generator has sufficient time to cool down before shutting down?
@ObamnaSoda513
Жыл бұрын
Hey nic when will u be doing fire alarm testing at the new middle and elementary school and maybe central plant
@nics-systems-electric
Жыл бұрын
Sometime maybe not this summer might have to wait till winter break
@marksmith-ew7ir
Жыл бұрын
Not bad I think I would have placed the relays on a bracket so if you need to replace relays you can do so with out pulling all those panels and screws. But it's was worth watching as you work hard sorting out the bug's.
@henrydoesstuff213
Ай бұрын
Now it acts like a generac! 😁
@GaryBeltz
Жыл бұрын
I would try this except the generator we have is a pull string so I'd either have to buy a different generator or somehow convert the pull string into a battery start first.
@nics-systems-electric
Жыл бұрын
Yeah that is a good point I should've added that in the video that the generator has to have electric start
@SodiumInduction-hv
Жыл бұрын
Wow! Keep up the awesome content!!
@nics-systems-electric
Жыл бұрын
Thank you will do
@enricodigi
Жыл бұрын
Have you got new cameras as they now say kami instead of yi?
@nics-systems-electric
Жыл бұрын
No they just change the name
@enricodigi
Жыл бұрын
Ok
@IanGSully
Жыл бұрын
When you were telling that story about that PVC box that the electrician ran over, are you talking about Jamie or another guy, I assume it's Jamie but idk lol.
@nics-systems-electric
Жыл бұрын
Someone else
@EverythingTech70
9 ай бұрын
Can you share a wiring diagram for everything? Also what model ATS do you have?
@nics-systems-electric
9 ай бұрын
Check out my ATS installation video
@Eric_Rosen
Жыл бұрын
so if the generator runs out of gas does it stop automatically before it runs out or will it run out dry?
@nics-systems-electric
Жыл бұрын
It'll run until there's nothing left there is not way for the controller to know how much fuel is in it
@EmilyMorgan
Жыл бұрын
When the power went out the UPS next to the second camera stopped the outage
@liamfaulk9107
Жыл бұрын
you should put a fire alarm system in a bus
@Bob-cx4ze
3 ай бұрын
$800!? That sounds exorbitant for what seems like a few voltage sensors, relays and timers.
@nics-systems-electric
3 ай бұрын
Not many other options for me to use
@domlimited1264
Жыл бұрын
good content
@nics-systems-electric
Жыл бұрын
Thank you
@tjlingram
2 ай бұрын
You will come to regret using those wire taps. Trust me. They always, always fail. From cars to household appliances, they always fair
@nics-systems-electric
2 ай бұрын
In that case I will replace them when it happens
@RuelGubaton
2 ай бұрын
Gdmrning sir,please give me a diagram
@beingsneaky
3 ай бұрын
no links??
@ken6x6
10 ай бұрын
I AM GRAT TO GET A FIRE ALARM SYSTEM IN MY HOUSE 😮😢
@applebottomjeans7145
Жыл бұрын
upgrade to windows 10
@chrispratt7363
Жыл бұрын
First
@ObamnaSoda513
Жыл бұрын
no one cares bruv
@chrispratt7363
Жыл бұрын
@@ObamnaSoda513 I know
@DarkySabertooth
10 ай бұрын
i was looking to do something like that with a generator from princess auto o.o i hope it will work when im able to finally able to get there
@nics-systems-electric
10 ай бұрын
It's definitely a good way to automate a portable generator if you don't have the utilities required for a standby generator. As long as you are patient and some electrical knowledge it can definitely work.
@DarkySabertooth
10 ай бұрын
@@nics-systems-electric thing is i do have natural gas how ever getting a standby generator installed is nearly 10-17k full install when the gen is only 1-3k and being disabled i don't have that kind of money to have it so i will have to go the next best rout i can