Hi sir I’m rana from Bangladesh.i living dubai. Control panel technician.
@John-qr4kf
Жыл бұрын
Get in touch with me through, johnmunam@gmail.com
@1978solomon
2 жыл бұрын
Dear sir' once switched on vfd its showed 0.00 only how to set the frequency
@John-qr4kf
2 жыл бұрын
Make sure drv is set 1. You can directly loop cm,p1 and p5, one of the option i have done there. The do your speed settings at F20,which is a jog,if at all you are running on constant speed. Incase you are running from outside reference 0-10v dc,just loop cm and p1 only.
@John-qr4kf
2 жыл бұрын
You can as well watch another video of mine. Vfd ls ig5a running locally from the Keypad and remotely.
@technicalcentar2476
3 жыл бұрын
Lslv - H100 VFD ka video
@John-qr4kf
3 жыл бұрын
Baatmi
@noerodriguez7756
3 жыл бұрын
How i can programin Contact 3A 3B 3C?
@ozilh2826
28 күн бұрын
Bagaimans bila muncul OCT,solusinya🙏
@John-qr4kf
28 күн бұрын
OCT is over Current. You can check your motor. Check the output cables whether there is a short.
@ozilh2826
28 күн бұрын
@@John-qr4kf saya sudah mencoba melepas kabel ,tanpa motor. Inverter tetap masih kode OCT
@John-qr4kf
28 күн бұрын
@@ozilh2826Incase you have disconnected both the motor and the cable and still the OCT indication is there,then the IGBT (SCR/Thyristor) are faulty.
Пікірлер: 18