Thank you Rao. I didn't know you also watch this channel
@rameshwarlalgupta6503
8 ай бұрын
Sir your video is helpful for me thank you
@powerplantguru007
8 ай бұрын
Thank you for watching my videos
@kanchankumar-pm9ox
Жыл бұрын
nicely explained 👌
@powerplantguru007
Жыл бұрын
Thank you for your support 🙏
@gauravkapoor2489
Жыл бұрын
Please make a video on ISO and Droop also...
@brahimizohir4411
11 ай бұрын
Thanks for your i have problem The turbin is pamping when we put in mode synchronisation so we have pamping in GCV valve the but befor mod synchronisation all the system ok speed and frycenc can you help me
@powerplantguru007
11 ай бұрын
Hello sir Each machine is different and I have very little understanding in the problem statement by reading the comments. If you need specific recommendations, please write to us dgna.creator@gmail.com. We will provide our consultancy with our expert team, it will be chargeable as we bring different experts for that.
@gustavomarcelo7250
Жыл бұрын
Sir.In the video it shows speed control loop with droop.But if it is in isochronous,how does the loop works or looks like?
@powerplantguru007
Жыл бұрын
Hello, thank you for watching my videos. Please watch my another video for the concept on droop and isochronous mode
@gustavomarcelo7250
Жыл бұрын
@@powerplantguru007 I mean, from the loop, you see Droop value been multiplied with the error signal.If in iso, then the value will be zero,zero multiplied with error signal= 0 FSR? Confuse with the loop if we are in iso,not the concept of isochronous. Or this loop not applicable when in isochronous and use other loop?
@syed_taha_ahmed
Жыл бұрын
I'm very confuse with two concepts One is droop and other one is ROCOF In droop setting we have given reference to markvi of 4%. But I've observed data in PI trend that during certain values of frequency 50.6 hz the load increases because cpr increases. but after that load will start to decrease when igv is lowering the angle. This load drop happens due to temperature control as ttxm reaches ttrx or due to speed control .If machine are at base load Secondly how rocof is different from speed/temp control
@powerplantguru007
Жыл бұрын
Thank you for watching my videos. I am not sure about ROCOF
@syed_taha_ahmed
9 ай бұрын
@@powerplantguru007You've said that the difference between TNR amd TNH will change the value of FSR. I've observed that as frequency drops from 50 Hz the output of machine reduce when at baseload. As Speed cannot be increase of grid connected machine.
@gauravkapoor2489
Жыл бұрын
Sir what is max valve of FSR oat base load ....... I am from fertilizer sector & our GT FSR gradually rise from 63-64 to 73 at same load ......... .....is it normal or have any problem?
@powerplantguru007
Жыл бұрын
Hi Gaurav Due to the busy schedule i couldn't create fsr video quickly, but my latest videos on FSR are available. To answer your questions., FSR may vary at the same load it has a relationship between air to fuel ratio. At the same load of air temperature varies or humidity varies FSR should change, because for a new set of air parameters max fuel quantity may be changed. You please observe this relationship and let me also know what is happening. kzitem.info/news/bejne/yIFmqXero3Rlh4I
@usamamajeed1300
Жыл бұрын
Sir I am waiting for DLN combustion system in industrial turbines please
@powerplantguru007
Жыл бұрын
Hope you have watched the new video on DLN
@usamamajeed1300
Жыл бұрын
Sir bundle of thanks I have some questions if you can share your insta I'd or Facebook
@eliyaskhan8008
Жыл бұрын
Very informative video 🥰 please if possible make in Hindi..😊
@powerplantguru007
Жыл бұрын
Thank you. I hope you have seen Hindi Version.
@ovrosparrow3948
Жыл бұрын
Make a video about process alarm of Mark vi and trouble shouting
@powerplantguru007
Жыл бұрын
Sure
@rohityadavraghvan
Жыл бұрын
Please make a video on Droop and Isochronous mode.
@powerplantguru007
Жыл бұрын
Yes. Sure
@gauravkapoor2489
Жыл бұрын
For single Gas turbine .......
@devivara1162
Жыл бұрын
Sir what is ejector???why it is used??
@powerplantguru007
Жыл бұрын
Hi Devi. Ejectors and used to evacuate air or any residual gases from any vessel. In case of power plant we use it with condenser to remove air and create vacuum
@powerplantguru007
Жыл бұрын
Vacuum is created so that steam turbine can give give more output
Пікірлер: 33