Thank you sir. Because of toure picture of the inside of youre sniffer, I located my sniffer on a champion 4500 inverter duel fuel. My sniffer dont look like yours.but its got that little blue bow with the round on the outside of it. Its in tray mounted with 2 screws and 3 wire sets going to it. For people with my generator looking for it I want to tell them here to pull the side panel off that is the same side as the pull cord and oil check and the propane attachment. As youre facing the machine, the sniffer is on left side upper. It has 3 seperate wire harnesses going to it. The blue sniffer with round white in the middle is at bottom of that box tray with the wire harness at the top im going to take it off Nd wrap that thing in clear box packing tape. See if that stops the sniffer from shutting down my generator. Its outside and the sniffer shuts it down when there is no wind or if the wind is hard at the backside. It blows the exhaust back into the machine vent. I put a fN on the machine. It still shut down. I want to thank this video guy for showing me what to look for. I had some other thing picked out as a sniffer. It wasn't and im glad I didn't do anything to the other thing. Thats over Bove the dip stick.
@stickys69
17 күн бұрын
I have a w2100i generator I cut the yellow wire with the green stripe still doesn’t start I don’t get y
@MichaelOhara-l7c
20 күн бұрын
thank you, my generator is running!!!
@ShowboatHK
20 күн бұрын
Almost did this on my 9500w but turning the switch to off for a few minutes seemed to reset it.
@philliphall5198
Ай бұрын
Can not hear you, please redo the volume and turn it wide open 😊
@MrLightingstar
Ай бұрын
Thanks for the tip buddy
@philliphall5198
Ай бұрын
Having other co testing devices is also a great idea and I would use the switch way
@user-ed7nl4ns3j
Ай бұрын
Cutting the green and yellow wire made my day. Was getting so flustered.. it worked
Ай бұрын
Excellent video! Thank you very much so much details. Subscribed!
@adriantinoco18
Ай бұрын
Can you help me out with mine i have the schematics but cant send them its a westinghouse wgen9500c the colors are totally different
@aaornmmatchette
2 ай бұрын
Thanks. I have my larger 9400 watt Firman in a purpose built shed. It would trip the sensor even with the doors open and I had the exhaust vented out the side of the shed. I had to jump the two black wires on mine. the sensor is behind the main panel above the start knob. You can access the wire harness without removing anything.
@mbeacher1
2 ай бұрын
Thank you
@y.m.i.hauling2746
2 ай бұрын
I have the same WH03242 generator. I removed the CO Module and noticed a lot of corrosion, I opened it, and there was corrosion all over the box and on the actual board. I ordered a new CO module from firman, last Thursday and it finally showed up today. I taped the sensor and all the vents with foil tape BUT it did not work. I am thinking that all the corrosion might be the problem with my generator, I will try method 2 next since I'm on the road and really need my generator. Thank you
@darrenbellouny9017
2 ай бұрын
Great video a bit worried about buying genset with CO sensor. Less worried now. Seems to be a lot of CO sensor complaints.
@MarioBrosseau-zi3yp
5 ай бұрын
I have a T08072. The jumper solution worked like a charm. The wires are both black in my case and the connector is hard to reach on this unit. My generator is in a cabana far from the house with two lateral door on opposite sides. This thing kept on stopping every 10 minutes both doors wide open even with a large fan blowing air from the outside. Big thank you to you, problem solved. The company did not want to help at all. Thank you, Thank you, Thank you
@fioraval
5 ай бұрын
cannot find co sensor on Firman T07573
@grace321181
6 ай бұрын
Excellent explanation of the problem and your various solutions for dealing with it. Thank you for sharing. 😀
@dentech987
6 ай бұрын
Just bought.a refurbished unit on ebay and was about to return so I'll give a try since I'm getting a blinking yellow Co2 fault.. Thanks a bunch for posting.
@keithrichards8695
7 ай бұрын
Thank you for your video, I've just purchased a Firman TO7573 and managed to jump it, using small paper clip. For the TO7573 it's the 2black wires, then wrapped the connector with electrical tape.
@Migou33333
4 ай бұрын
hi .... hope you can help me .. got a t07573 from costco as well ... without removing the sensor from the generator can i simply pull off the white connector to remove it from co2 sensor for easier access .. then jump it ? please give me your input thank you
@keithrichards8695
4 ай бұрын
@Migou33333 Yeah, just disconnect the sensor and jump it, make sure you secure the clip with a piece of electrical tape so it stays in place. Hope this helps
@Migou33333
4 ай бұрын
@@keithrichards8695 thx !!!
@joewiensband
3 ай бұрын
Anyway you can guide me to the sensor? Is it in the same spot as his in this video? I have the same model that you have. I'm trying to locate it. I see something that looks similar but it's got two yellow wires going into it. Let me know if you can. Thank you.
@Migou33333
3 ай бұрын
@@keithrichards8695 yep ... jumping 2 black wires worked perfectly ... thx !!!
@MrF20accord
8 ай бұрын
Your the man I tried your method on my p08008 and everything work with out that pos Co module 🍻
@stevecipolla3508
8 ай бұрын
You are the man. My module needed to be replaced and I only use it outdoors anyway. Jumped it and power is back on. Thanks so much
@michaelvolin9749
8 ай бұрын
Thank you for the great video with clear instructions. Great job.
@navydave1
9 ай бұрын
I have a similar sensor on my Champion 2500 inverter generator. Do you think covering the membrane with superglue or some sort of silicone sealant would work or would that seep into it and cause a fault?
@pilotdog68
9 ай бұрын
Mm I'm not really sure. Maybe worth a try
@navydave1
6 ай бұрын
@@pilotdog68Update. Pulled black wire that goes to Engine Stop Micro Switch. Works like a charm. Vid on my page.
@DanDan-nv1yt
9 ай бұрын
Hi , At 5.18 minutes. you said the CO sensor grounds out the ignition module when it senses CO, I’m wanting to install a thermal switch to shutdown the generator in the event of Hi temps. What wire coming out of the CO sensor is grounding out the ignition? Wanting to break into that wire and install a N.O thermal switch that goes to ground and will shutdown the generator. Alternatively you said the gen won’t run without the CO alert,is there a single feed wire to the CO that I can interrupt with a N.C thermal switch to achieve a shutdown ? Thanks
@pilotdog68
9 ай бұрын
Hi, the yellow and green wires that I talk about jumping at 3:10 are the wires that are being grounded to shutdown the ignition. Alternatively the Brown wire provides power to the CO module, so interrupting that would cause a CO fault and shut it down as well. Though if I remember correctly that method would not be instantaneous, it takes a few seconds delay for it to sense a fault. You can see the wiring diagram on Firman's website, or at the top right at 8:46
@DanDan-nv1yt
9 ай бұрын
@@pilotdog68 Hi, thanks for responding so fast! A little confusion on the three yellows… to clarify , when the CO unit detects CO it grounds the yellow that goes back to the ignition coil (yellow next to green on the CO unit) and cuts the motor? If I splice one side of a N.O thermal switch into that yellow (the other side going to ground) in the event of an over temp scenario the thermal switch closes and the motor will shutdown? Want to be sure before I cut wires… With using the brown instead, when you say seconds is it under 10 seconds? Appreciate the help
@larryisaac8988
10 ай бұрын
when you cut the green and yellow wire what happen?
@pilotdog68
10 ай бұрын
The module will lose access to Ground so it can't pull down the ignition signal.
@larryisaac8988
10 ай бұрын
@@pilotdog68 mine won't start
@johnsteed99
2 ай бұрын
@@larryisaac8988 I believe after you cut that wire, you need to push the plug back into the socket like it was originally for it to start.
@MrMAKAK17
10 ай бұрын
anyone know how to do this on a t07573?
@pilotdog68
10 ай бұрын
It should be about the same because it uses the exact same part number CO sensor. You just have to dig around and find it on yours. here is the picture from the parts diagram. imgur.com/a/isHv11p
@cvdb-yx6ej
10 ай бұрын
Great video. Thank you. I have a Firman P09201 11,400/9200w that shuts off frequently from co alert. The Firman P09200 control panel is boxed in and I am unable to access it without removing the gas tank etc. Do you have any suggestions? Thank you very much. Again, excellent video!
@pilotdog68
10 ай бұрын
It's unlikely that it would be inside the control panel box because the sensor has to get air to it, but it's certainly possible you will have to remove the fuel tank to see it.
@pilotdog68
10 ай бұрын
That model generator seems like it has been retrofitted with the CO module because i cannot see it on the parts diagram shows an older version without the CO sensor.
@airsoftsnake
10 ай бұрын
I have the T09275 11,400/9220w , tri-fuel, and the sensor is on the oposite side of the exhaust, close to the control box, but not inside it. I didnt disable it yet. Close to the recoil starter (the pull-start)
@flashpilot6934
11 ай бұрын
Thanks pilotdog. I have the same generator and it kept conking out every time the wind blew. Your paper clip jumper mod did the trick.
@jakecanon9620
11 ай бұрын
FYI The firman tri fuel is 2 black wires
@giankieluna
Жыл бұрын
Well if i put the sensor inside of a condom and closes it with a ty-rap, will that work?
@moommmoom
Жыл бұрын
Just removed the green yellow wire pin from connector block, with a 1mm phillips screwdriver, "easy reassemble". machine works great now, Thank you
@rodneyerickson6088
Жыл бұрын
Perfect
@byroncollett9328
Жыл бұрын
Need some help identifying correct wires on my firman model w03386. Appears to be yellow and brown. How do I attach a pic?
@pilotdog68
Жыл бұрын
Unless the manual for your generator is wrong, it's still the green and yellow wires that come out of the same white sleeve together. But yours has remote start, so like I said in the video I'm not sure if you need to do anything with the blue wire or not. I'd try jumping green and yellow and see if it works before messing with blue.
@byroncollett9328
Жыл бұрын
I think you are right. I can’t pull it out very far to get a good look. I’ll get closer in tomorrow. Thx
@byroncollett9328
Жыл бұрын
Success jumping green and yellow. Remote start not affected. Thx much
@bubblegum751
3 жыл бұрын
Is there a way to unplug the freaking fuse to make it quiet 🤐
@donjohnson1524
6 жыл бұрын
How did you mount the magnet? I used super glue but it only works for about 30 days then the glue gets brittle and does not hold.
@blancajameel6689
6 жыл бұрын
I'm having this problem now I called Ford and they are charging me about $500 I wish I knew how to fix this I know it looks easy but I wish you would have started from when you cut the wire how you put that split in it LOL what that black thing around it is
@robbiesheene3270
7 жыл бұрын
I have a 2013 Ford Edge with the same issue. This fixed it. GENIUS!!!!!!!!!!!!!!
@drewl9133
7 жыл бұрын
so what magnet switch are you talking about this is genius
@pilotdog68
7 жыл бұрын
I know it's late for you, but maybe this will help other people. Exact alarms I harvested my sensor from: goo.gl/qcKsNn but if you don't already have them on hand it is cheaper to just buy the sensor itself online, search for "Normally open magnetic reed switch".
@scottmay8217
7 жыл бұрын
This problem has driven me crazy for years!!! I even had to resort to removing all of my interior lights to keep the battery from dying! I tried your fix and it worked perfect!! Thank you!!!!!
@vegafoxxx
7 жыл бұрын
Good Lord!!! look at all those T taps. Good info though. Thanks
@scottwood1388
8 жыл бұрын
had this issue on my 2011 edge and followed the process in this video. The switch I used had both normally open and closed contacts so I just used the one that worked. Thanks for the info.