ShaikhAbuKhalid Protection Master Anti-convuls-ant
EXTRAORDINARY Work- 1:05
- 5 ай бұрын
How to make Down OPGW ringa and Jointbox from 132kv transmussion line circuit for checking fibrecore
- 1:36
- 6 ай бұрын
How to calculate the distance of breakage fiber core from ODF panel with the help pressure point sdh
- 1:05
- 6 ай бұрын
How to read JDSU OTDR meter graph to read the pressurepoint of single mode fibre optic cable for ckt
- 1:23
- 6 ай бұрын
How to use OTDR meter of JDSU for checking the fibre optic core losses length of distance between...
- 1:05
- 6 ай бұрын
How to Operate the JDS U otdr meter to check the pressure point lengthand losses of fibre optic link
- 1:22
- 6 ай бұрын
How to pull and elevate the 4-quadcore OPGW jointbox ring at 132kv transmission line circuit by CPM.
- 1:04
- 6 ай бұрын
How to operate the splicing machine for 120 fiber splicing for quad(4) direction OPGW cable 32 core.
- 1:03
- 6 ай бұрын
How to do splicing of 4Quad jointbox for OPGW of 132kv transmission line circuit for MemonGoth link.
- 1:18
- 6 ай бұрын
How to arrange fibre of 4 tube of quadcore jointbox for OPGW cable from 4 different location/grids..
- 1:04
- 6 ай бұрын
How to make setup of splicing of quad core 120 fiber jointbox for 132kv transmission line circuit...
- 1:04
- 6 ай бұрын
Daru madari aya
- 1:23
- 6 ай бұрын
How to do splicing of OPGW jointbox with UGFOC in gantry area of 132kv transmission line circuit....
- 1:10
- 6 ай бұрын
How to do splicing of OPGW jointbox with UGFOC in gantry area of 132kv transmission line circuit....
- 1:19
- 6 ай бұрын
Well done for successfully closure of landhi/ Kda malir korangi opgw stringing 37 KM project by CPM
- 1:09
- 6 ай бұрын
Preparation of pulling of OPGW 132kv with 50KN tentioner and tractor puller for LAN-newLan-johar/caa
- 1:28
- 6 ай бұрын
How to do survey of OPGW tower for safety NEBOSH of transmission 132kv LAN-NewLan-CAA&Johar a...
- 1:30
- 6 ай бұрын
How to do OTDR with LC - LC patchcord of fiberoptic cable singlemode cable in ODF panel in grid132kv
- 1:41
- 6 ай бұрын
tell me the next story
- 1:37
- 6 ай бұрын
How to extract the battery load testing report from battery loadtester for 48VDc 185 AH battery bank
- 1:03
- 6 ай бұрын
How to check the serial 101 scada data of 132kv grid station for transmission line circuit for LT
- 0:18
- 6 ай бұрын
How to check the SCADA 101 data for telecom PLC equipment of teleprotection voice data and PABX grid
- 1:18
- 7 ай бұрын
How to adjust gain for end to end teleproteleprotection commands DDT and Permissive on PLC SDH
- 1:04
- 7 ай бұрын
How to do terminations of droppers of bushing CC post insulators Work remove support insulator220kv
- 1:03
- 7 ай бұрын
Пікірлер