it is operated by a battery operated remote control? is it hardwired? Does it have blackout blinds? Seeing your in the UK, won't help me much in USA...
@leighatkins22
3 ай бұрын
This video should be renamed: "What Australian bird call is that?"...
@BrownPaperBag02
6 ай бұрын
Freaking love a skylight
@rski1036
10 ай бұрын
Horrible installation video. Where is the electric ???
@Oscar-te6xu
11 ай бұрын
How would u insulate the vertical sections? As per regs.. thanks
@jonathanjoensen2679
Жыл бұрын
I would have glued a drip nose profile to prevent water from even reaching the bead of sealant.
@jimmys.8062
Жыл бұрын
nice details, thanks for sharing. I like the end where it shows the caulk lines underneath.
@NaveedBradford
Жыл бұрын
Nice informative video, please send me link where to buy sky light from thanks
@uy-scutipacific6398
Жыл бұрын
Did He just say 6x2?????? Like wtf man lol isn't it should be 2x6 even easier to pronounce 🙄 😆 😂
@kieranardaen-webb9913
Жыл бұрын
Does these sky lights fit on to felt finished roofs?
@garycrosby5703
Жыл бұрын
What is the fall across the 800mm rooflight, it looks about 30mm to 0.
@sarisextensionstest8644
Жыл бұрын
10 cm per meter
@arbit3r
Жыл бұрын
@@sarisextensionstest8644 1:40 40mm per meter correct fall so 30 mm is right for an 800mm wide skylight.
@williamosullivan3553
Жыл бұрын
What size was this skylight??
@skylightsone3959
Жыл бұрын
The video was shot a long time ago, we can't remember the exact size of the unit, sorry.
@dshathaway
Жыл бұрын
Can the 6° lean be across the width of the unit, or does it have to be the length? Looks like it is across the width in the video?
@zandersthorn476
2 жыл бұрын
Could the glass be lifted by hand if you don't have suction pads ??
@londonskylights8559
2 жыл бұрын
Yes, it can. For bigger sizes, please use suction pads to avoid damage.
@ktmidol
2 жыл бұрын
If anytime an earthquake hits the UK then all that steel beams will fall out and injure people. It is literally hanging on top of 1-2 layers of brick/block. Why do they not use pillar steel foundation like in other countries. Just my thoughts!
@northeastcorals
2 жыл бұрын
Would this be the exact same method for EDPM? I've searched YT & can only find videos of these types of skylights being installed on GRP & every EDPM roof seems to use skylights with trims/flashing around the sides. Cheers.
@tc1420
2 күн бұрын
Hi Did you ever figure this out?
@northeastcorals
Күн бұрын
@@tc1420 I couldn't get an answer anywhere so I just decided to instal both my EDPM & window in a similar way as in this video. The only thing I did differently is rather than having the EDPM completely cover the very top horizontal face of the timber frame that the window is adhered to, I instead cut it back from the inside edge by an inch. In other words the EDPM rubber still laps up the vertical part of the timber frame, then turns 90 degrees to cover the top horizontal face but stops an inch before hitting the inside edge, which leaves an inch of exposed wood all the way around the inside edge of the frame. My logic being that I wanted at least some area to be a direct bond between the window, sealant & wooden frame, rather than the frame only being bonded to EDPM, although I bonded the glass to both the timber & EDPM just to make sure. No idea if this was the correct thing to do but 2 years later all seems to be well with the 2 windows I installed. I also painted the wooden frame on the inside bit that remains visible, where it meets the internal face of the window with rubber roofing paint as I suspected the windows may be prone to a bit of condensation during the winters & I was correct, so I'd also recommend treating this part of the timbers with something appropriate.
@tc1420
Күн бұрын
Thanks for the info. Really helpful.@northeastcorals
@northeastcorals
Күн бұрын
@@tc1420 No probs
@aledjonesccc
2 жыл бұрын
I've not fitted my window yet but I will be over the next few weekends. Can you clarify the degrees of fall required on the glass? The website stipulates 8-10° as a minimum, but the video says around 6°. Also, a the instructions, guides and diagrams show the use of structural adhesive as well as the sealant, could you clarify the actual requirements? Thanks.