Electrical Passionate
I am Er. Sisir Kumar Karmakar,AMIE(Electrical) C.Eng-I, Ex. Divisional Engineer(Electrical),WBSETCL.It is an Educational channel based on Electrical Engineering and Technology.The electrical engineering students,technicians and aspirants who wants to have gathered general conception and knowledge on operating procedure and usage of different testing and measuring Instruments like Megger, Multimeter Earth Resistance Tester used for maintenance of electrical equipment in Lines and Sub-Stations may visit the channel.Testings of CT, PT,Transformer,Circuit Breaker,density monitor,anti pumping,Protection and control of Lines,Transformers and usage of CT, PT and Relays,Study of electrical drawings, making of Matching circuit diagram between control and equipment, Motor control and protection, DOL,Star -delta Starter wiring and how it operate,Erection of Two pole mounted Distribution Transformer, Lines, AB cable with accessories , motor operated Isolator, interlock ,T D Relay will be included
- 12:27
- 28 күн бұрын
TRANSFORMER WINDING DC RESISTANCE TEST/DC RESISTANCE OF WINDING/TEST OF DC RESISTANCE OF TRANSFORMER
- 14:35
- Ай бұрын
CURRENT TRANSFORMER NAMEPLATE DETAILS EXPLANATION/CT NAMEPLATE DISCUSSION/RATING PLATE DETAILS OF CT
- 13:23
- Ай бұрын
CURRENT TRANSFORMER/CT SATURATION/ KNEE POINT VOLTAGE/STABILIZING RESISTANCE-CALCULATION
- 19:27
- 2 ай бұрын
Protection of Transmission Lines/Directional Relay/Parallel Lines Protection/Unidirectional Relay
- 3:44
- 2 ай бұрын
GENERAL ARRANGEMENT OF 1-PHASE 2-WIRE SYSTEM ON PSC POLE/GA OF LT LINE VERTICAL FORMATION 1PH,2WIRE
- 11:00
- 3 ай бұрын
TERTIARY WINDING OF TRANSFORMER/FLOATING OF NEUTRAL/SHIFTING OF NEUTRAL/STABILIZING WINDING
- 3:19
- 3 ай бұрын
COIL EARTHING DETAILS/EARTHING COIL/ELECTRICAL EARTHING/SPIRAL EARTHING /EARTHING SYSTEM
- 5:37
- 3 ай бұрын
DIST.TRANSFORMER MEGGER/INSULATION RESISTANCE TEST PROCEDURE OF A DISTRIBUTION TRANSFORMER
- 9:09
- 4 ай бұрын
Use of DC Fault Locator for detection of DC Earth Fault/Detect DC Earth Fault by Fault Locator
- 10:24
- 4 ай бұрын
Detect DC Earth Fault by a Multimeter & a Lamp/DC Earth Fault Detection without a Fault Locator
- 9:27
- 4 ай бұрын
Measurement of Earthing Pit Resistance/What is Earth Resistance/How to measure Earth pit Resistance
- 6:06
- 6 ай бұрын
TRANSFORMER COOLING SYSTEM/COOLING SYSTEM OF POWER TRANSFORMER/DIFFERENT COOLING OF TRANSFORMER
- 4:34
- 6 ай бұрын
Through Fault/ internal fault/ inter-zone fault of transformer/through fault in transformer
- 16:39
- 7 ай бұрын
TTR test of Transformer/Transformer Turns Ration Test
- 10:25
- 7 ай бұрын
Stability test of Transformer:REF stability Test: Calculation of currents for stability test
- 6:14
- 8 ай бұрын
WORKING PRINCIPLE OF RESTRICTED EARTH FAULT PROTECTION/REF PROTECTION OF TRANSFORMER- EXPLANATION
- 6:48
- 8 ай бұрын
BATTERY IMPEDANCE TEST/TESTING OF BATTERY IMPEDANCE
- 9:25
- 9 ай бұрын