I'd run when coupled motor what parameter to select.
@akshardas6527
Жыл бұрын
Hello, Sir, Nice to watch your video and your help community via sharing your knowledge. I’m Indian and live in USA and working as volunteer in one religious’ facility for kitchen related activities. I m not electric knowledge guy but whatever I know I m explaining you. I have one question for buying one equipment with European standard motor. In USA we have 60hz power supply available in 3ph.Here is several types of models has different types of motor installed in it Like bellow #1 (3ph.... 220V..... 50hz.... 5.5kw) #2 (3ph.... 380V..... 50hz.... 5.5kw) # 3 (3ph.... 400V..... 50hz.... 11kw) #4 (3ph.... 400V..... 50hz.... 7.5kw) Can we run any of above motor (equipment) with 50hz via using VFD? or what can we run via Delta connection? ( I heard from someone ) Please guide
@aforautomation
Жыл бұрын
Yes you can run all 50 Hz motor ,choose vfds accordingly,input power of vfd should be 60 hz.
@urveshi
3 жыл бұрын
Sir delta vfd ms300 or el series me motor auto tuning kese karte he ?? Plz sir help 🙏me...
@maheshkumar-ng9kj
3 жыл бұрын
Schneider atv 312 parameter setting video
@pwnsharmacartoons3931
5 жыл бұрын
thanks sir
@RajatKumar-pl2xw
4 жыл бұрын
Sir,auto tuning ka fayda kya h,hm seedha hi quick start parameter daal ke bhi drive chalu kr skte h
@aforautomation
4 жыл бұрын
kzitem.info/news/bejne/2YSd1Xt8hYhzeoY
@shashankkumar7770
3 жыл бұрын
Autotuning 1 and 2 Kya selection
@kaatnikaatni9012
5 жыл бұрын
Sir what is DC Bus voltage you mention in video?
@aforautomation
5 жыл бұрын
you know vfd first converts mains input into DC .if supply voltage is 415 then DC voltage is about 580V DC.this DC voltage varies as per load conditions.
@vctech4954
5 жыл бұрын
Sir Input me L1 L2 me solar DC 400 voltage de sakte h kya?
@aforautomation
5 жыл бұрын
NO.thease terminal are for AC mains input.this drive is not designed for DC input
@aforautomation
5 жыл бұрын
you need an inverter for converting DC to AC first.or some drive are designed for DC input
@vctech4954
5 жыл бұрын
Sir input Kar sakte h Mene Dekha h . Jo invt ki vfd aati h usme experiment Kiya thaa
@aforautomation
5 жыл бұрын
we are using powerflex 700 drive with DC input.but its mentioned in their catalog that you can run with DC input.
@vctech4954
5 жыл бұрын
Sir wase BHI AC supply 3 phase rectifier me hi Jake DC hi to Banti h to q n ham DC supply rectifier me de k DC se AC H bridge ban jayegi or vfd Kam Kar Sakti h
@PintuVerma-cv9uk
4 жыл бұрын
Sir VFD kaise start krna chahie ,,, starting processing kya hota hai,,,mujhe interview me pucha gya tha
@aforautomation
4 жыл бұрын
ita very good topic for me.i will make a detailed video .
@PintuVerma-cv9uk
4 жыл бұрын
@@aforautomation Thora jaldi sir
@MuhammadArslan-vl7ln
4 жыл бұрын
How to run a motor above his rated frequency using vfd?
@aforautomation
4 жыл бұрын
just set max speed upto 70or 80 Hz and speed reference scaling as per set frequency (70/80), in case of variable load we should stick yo nameplate speed
@MuhammadArslan-vl7ln
4 жыл бұрын
@@aforautomation motor rated frequency is 50 hz . Can we run it at 70 hz?
@aforautomation
4 жыл бұрын
@@MuhammadArslan-vl7ln yes you can run it on 70 Hz but you will not get rated torque at this speed.if torque is not required so much you can run it on 70 Hz..
Пікірлер: 39