I recently used a diverter similar to the one used in this video to add a hydraulic winch to the front dozer blade circuit of my kubota kx121-3 excavator. Works well except that when switching from the blade to the winch the blade cylinder loses pressure and the blade drops. Am i missing something in the hook up? Ideally I would like the blade to hold in whatever position it was in prior switching to the winch function Thanks for your thoughts
@Hydraulic.Online
Жыл бұрын
Hi Brad These valves are available with what is called Open or Closed centre on switch over, from what you have written it seems you may have an open centre on switch over. Check if what to were supplied, if it is an open centre valve, you should try and exchange it for a closed centre on switch over.