-Join our updates list for an email strictly from us for new videos, articles, products and website features! www.acservicetech.com -Our Website has FREE Videos, Calculators, Podcasts, Articles, Tips, Quizzes, Q/A: www.acservicetech.com -Facebook Tips: facebook.com/acservicetech -Tools we use, Our Book, Workbook, and Quick Cards: www.amazon.com/shop/acservicetech -Our E-book, Paperback, Workbook, Quick Cards, Powerpoint, www.acservicetech.com/ac-book -Our E-book: play.google.com/store and search "ac service tech" -Spanish Book & E-book: www.acservicetech.com /store
@jimbola77
4 жыл бұрын
thank you Craig for sharing!!!! awesome presentation!!!!.
@etlawson6939
3 жыл бұрын
My fieldpiece gauges overheated and won't display. My boss is trying to get them service. I got to get an umbrella for them. Maybe a small air conditioner
@jimbola77
4 жыл бұрын
Dang!!!! I WAS WONDERING WHY I HAVE NOT GOT ANY NOTIFICATIONS!!!! OH WELL, IT IS WHAT IT IS!!!!.
@ishalljr
4 жыл бұрын
Will you be making your cards digital? I want to be able to access them wherever.
@dulalhossain5341
4 жыл бұрын
Thank you sir for good advice.
@marceloliveira6014
4 жыл бұрын
I prefer the old equipment!!!!! Can see better. But not with digital!!!!!!!!!!
@RPHDWideGlide
4 жыл бұрын
Another great video,I have a question though,what is your preferred method of checking airflow?I have the exact same manometer you have here but was thinking of picking up the hotwire anemometer as well.Most of the time the equipment data is not available on site and in some rural areas I can't check online.
@hkhsm359
4 жыл бұрын
Nice video and good knowledge. Thanks for sharing
@brandoncoffee8044
4 жыл бұрын
R410a single stage system. Outdoor temp 84deg indoor temp 77 deg. Suction pressure 171. Line temp 66 deg SH 6deg Head pressure 266. Line temp 70deg. SC 17deg. Txv system 4 ton ac unit with 4 ton uncased evap coil. 3/8 liquid line with inch and 1/8” suction line approx 20’. Can’t figure out why this is happening. Temp split is only 12-14deg at best. Airflow is good. Not sure on static pressure or cfm. Any suggestions?? Any feedback would be great!! I am only asking because I believe you have some of the best educational videos on you tube. Thanks for what you do!! I also have a pic of these readings from measure quick.
@pedros.c6742
4 жыл бұрын
delta T to low for me supose to be 18 20 split.should be air flow problem, no sure
@pedros.c6742
4 жыл бұрын
A litle over charge to
@ishalljr
4 жыл бұрын
What is the required subcooling? Per the name plate inside the unit if available.
@chuckdearruda6271
4 жыл бұрын
What does measureQuick suggest as likely problems? Liquid line temp should be more like 89 deg given OAT of 84 deg). mQ suggestions (flag in upper right corner) may be your best guide.
@chuckdearruda6271
4 жыл бұрын
If 70 deg liquid line temp is correct (with 88 deg condenser condensing temp and 84 deg OAT) you definitely need to consider line restriction.
@willhvac
2 жыл бұрын
Can you do a low air flow with a piston please?
@publicmail2
4 жыл бұрын
Good stuff and well concise explanation.
@acrepairnearme
4 жыл бұрын
Why sometimes SC is 0? Liquid line temp following with the saturation temp on the high side while charging. System has a TXV. R410. The only way to adjust the system is using SH method. To get 10 degrees SH. Condenser blowing hot. Good airflow. System works stable.
@acrepairnearme
4 жыл бұрын
VicPapefu thank you ill try to check it.
@edgar20109
4 жыл бұрын
Great video, thanks
@acrepairnearme
4 жыл бұрын
Another question. How to braze txv and not overheating is? (The tubes from the txv sides is TOO short ) and I have to remove the wet rug in order to be able to melt the rod?
@acrepairnearme
4 жыл бұрын
VicPapefu thank you for the response. Yeah, I've heard about this product, but never use it. Next time I'll try it!)
@phillipjoy1305
2 жыл бұрын
Great channel 😊
@F12255
4 жыл бұрын
Love the videos. Had a situation r407c with a 62psi low side 185 high side. 8 deg SC. 2 deg SH. Vapor sat was about 38 i believe. But my suction line temp was low. About 39 degrees. I was thinking airflow with the low SH and low suct line temp. Piston on a 4 ton unit. Weird how pressure seemed okay. Any input? Appreciate it!
@raulrobles2961
4 жыл бұрын
He doesn't reply unless you talking about purchasing his products
@F12255
4 жыл бұрын
@@raulrobles2961 lol good to know. Thanks
@corruptedbrain6
8 ай бұрын
@@raulrobles2961cap
@ejcsds
4 жыл бұрын
Sad that KZitem has decided not to send notifications anymore. Going to be lost revenue on both sides from me since I am not going to come and "check" my subscriptions! Great video again!
@pizzle1011
4 жыл бұрын
Thanks again I enjoy watching these videos. Between these and your book it's a great help/reference 👍🏾👍🏾
@mikev.1034
4 жыл бұрын
👍👍
@rondail5675
4 жыл бұрын
So low air flow can cause a problem. Can an over-sized unit cause low air flow, say only 12000btu needed but a 24000btu unit is installed? Is it better to be a little under-sized or better to be a little over-sized?
@raulrobles2961
4 жыл бұрын
Only be sized half a ton bigger. Never be undersized because you will have issues of home not cooling enough everywhere