happy holidays to all the hvac/r techs this has saved me on late night calls few times in my day also def
@rick00721
7 жыл бұрын
Nice video Dave. Its great to see someone that takes pride in there work :)
@bradmironik6137
6 жыл бұрын
I like that old school method. Simple and seems to work well.
@harrydickson4575
7 жыл бұрын
Excellent demonstration Dave
@frontiermarvin71
7 жыл бұрын
Thank you for the information!!! Merry Christmas !!!
@mikerefrigeration5736
3 жыл бұрын
I seen this setup before on an old step in cooler at a chinese restaurant. I had put a JC air coil in place of it and added R417C worked great. First time i saw an LP to control temp. Cool video.
@hvac01453
5 жыл бұрын
the reason for regulating the temperature through the LP control was to attempt to prevent the customer from screwing around with it. Lots of times, techs will remove the adjustment knob in a vain attempt to prevent tampering. The way I see it, if they screw up messing with the controls, they have to call you out and you get to bill them for your time. This only backfires if they wait till <a href="#" class="seekto" data-time="210">3:30</a> on Friday....
@aircooledtx
7 жыл бұрын
Old school we used these allot, but that was with R-12,22,502. Now refrigerants are blends with some are not quite as stable, so have to do set-up as Dave suggested.Good explanation ; Dave No-Cal~Refer
@franciscocuellar7072
Жыл бұрын
Excellent explanation! Thanks for sharing and keep up the great work
@scottk0623
4 жыл бұрын
Thanks for the information Dave
@gregomyeggo4529
7 жыл бұрын
Merry Christmas!!! Thanks for the information!
@NorCal-refrigeration
7 жыл бұрын
G. Salis merry Christmas 🎁🎄
@saltrue1555
5 жыл бұрын
Awesome video thank you very much for your teaching hope you make more of this
@RobHVAC
7 жыл бұрын
Merry Christmas Dave. Great vid. Looking forward to more in the new year.
@NorCal-refrigeration
7 жыл бұрын
Rob HVAC merry Christmas Rob
@hvacgabe5889
7 жыл бұрын
great video and demonstration, I'll be sure to add that to my reputoir. thanks man. have a merry christmas.
@NorCal-refrigeration
7 жыл бұрын
gabriel brown merry Christmas
@naserduskie7970
5 жыл бұрын
Thanks! Excellent video.
@marcoferreira226
2 жыл бұрын
watching some old vids you have some good stuff here
@whitesheatingairappliancer7101
7 жыл бұрын
Great video thank you. Merry Christmas.
@NorCal-refrigeration
7 жыл бұрын
Ron White merry Christmas
@soloryderrr
7 жыл бұрын
Very informative video thanks!
@liangsam2554
7 жыл бұрын
nice video. thank you , and Merry Christmas
@NorCal-refrigeration
7 жыл бұрын
liang sam merry Christmas
@daveydave9884
7 жыл бұрын
Good walk through brother. Merry Christmas
@NorCal-refrigeration
7 жыл бұрын
David Smith merry Christmas 🎄
@munana3
7 жыл бұрын
Gracias por hacer eso videos😎
@HVACinSC
7 жыл бұрын
Great video Dave! Have a Merry Christmas brotha!
@NorCal-refrigeration
7 жыл бұрын
HVAC in SC merry Christmas
@jonhvac
7 жыл бұрын
I really like the milk crate stand :) Very very good vid Mr. Dave.
@NorCal-refrigeration
7 жыл бұрын
Jon HVAC milk create stands are free. Lol
@MrLaffertyheating
7 жыл бұрын
Love the outro......west cooooaaaast!
@glennsepelak5113
5 жыл бұрын
I like that spaghetti liquid line and filter drier in the back ground
@heavydiesel
7 жыл бұрын
Alfa Laval used to run their milk tanks off low pressure controls, worked well with R12.
@johntrauger68
6 жыл бұрын
It did make sense. Plus, another way to skin a cat is always useful when dealing with machery. Thanks!
@edwardhvacr4815
7 жыл бұрын
Merry Christmas Very good explaining how they did with the pressure control but if you have a blend refrigerant it a lot hard to set .
@NorCal-refrigeration
7 жыл бұрын
Edward Hvacr it can be. Merry Christmas 🎄
@Bluecollarworkingman
6 жыл бұрын
This was helpful.
@juliocalvet9839
7 жыл бұрын
great vid keep I'm coming have a great new year.
@NorCal-refrigeration
7 жыл бұрын
Julio Calvet thank you!
@tcphvacr9950
7 жыл бұрын
Like the explanation of how to set up those switches as a thermostat, kind of the same concept the reach ins use with the bulb in the coil, nice and simple. I looked up that app after watching, like the slide option. RSD Notes for those interested.
@NorCal-refrigeration
7 жыл бұрын
tcpHVAC/R that's my main supply house. Great app has a level too.
@pedrojardim325
Жыл бұрын
Good stuff Dave We see. That controls still very interested
@lorenzoontiveros7875
7 жыл бұрын
Thanks again great video
@NorCal-refrigeration
7 жыл бұрын
Lorenzo Ontiveros your welcome
@eliseovalle2658
6 жыл бұрын
thank you
@AVR-hf1rl
7 жыл бұрын
great info Marry Christmas
@NorCal-refrigeration
7 жыл бұрын
Martin Gardner merry Christmas
@ryans5473
5 жыл бұрын
LPC switch used for a t-stat only works if you have a non-bleed txv tho...but then again walk in boxes usually are non-bleed and have start components to overcome the stored head pressure. But that's also good info if you come across a walk-in with a bad txv that's running on a temp control with a low pressure cut out...don't put a bleed/equalizing txv on there! Good video
@jeanettelawson5152
5 жыл бұрын
Great information.
@alphaomega5923
4 жыл бұрын
You know your chit mate too damn well! Please do a video on how to connect the duel pressure control please on a refrigeration system if possible.
@j.r.1223
4 жыл бұрын
Thanks!
@darinpugliese5103
7 жыл бұрын
Thanks Dave
@darinpugliese5103
7 жыл бұрын
Hit the town soul player
@philltafolla
7 жыл бұрын
great video Dave I like using that particular low pressure control , and as a universal temperature control I use the Ranco A12-700 and the cut in , and cut outs are at 37 cut in and cut out at 18 psig that works for me A12-700 bad ass tstat ...great video Dave
@NorCal-refrigeration
7 жыл бұрын
Felipe Tafolla I use part # 61-030 from RHS 21.00$ just like the A12701.
@philltafolla
7 жыл бұрын
Nor-Cal Refrigeration & H.V.A.C nice might give it a try ..thanks!
@RealityRenovations
7 жыл бұрын
hahaha the milk create! I get a kick out of all of these units you work on. All of the improvised dog houses and stuff are pretty damn funny.
@NorCal-refrigeration
7 жыл бұрын
Brad B it's like an island out here. Lol
@polishtheturdmickelson5473
7 жыл бұрын
Never seen a condenser sitting on a milk crate. And never will again lol. Must be a shortage on cinder blocks in California.
@NorCal-refrigeration
7 жыл бұрын
polishtheturd mickelson not my install just my repair at customer request. No more cinder blocks here due to earthquakes.
@polishtheturdmickelson5473
7 жыл бұрын
I know it was not your install. Why can't cinder blocks be used in California to support a condenser? I Really want to know, thanks.
@NorCal-refrigeration
7 жыл бұрын
polishtheturd mickelson u can use whatever u like here even a milk crate. Lol. There is no refrigeration police and I don't stock cinder blocks on the vangina.
@eliseovalle2658
6 жыл бұрын
i like your videos
@eliseovalle2658
6 жыл бұрын
i got it on 134a cut out around 1to 3 and cut in 20
@tiaandbuster
7 жыл бұрын
Merry Christmas Dave ........
@NorCal-refrigeration
7 жыл бұрын
Lloyd .Haight merry Christmas 🎄
@hardcooling
7 жыл бұрын
Merry Christmas bro
@NorCal-refrigeration
7 жыл бұрын
hardcooling merry Christmas 🎄
@20antman
7 жыл бұрын
Good video Dave. In most cases using a pressure control as a temp control on an outdoor condensing unit sucks. Your ambient temp fluctuates it changes your refrigerant pressures then causing your pressure control to cycle. They work good when the condenser is indoors. (Temp controlled environment to maintain a constant ambient temp.
@NorCal-refrigeration
7 жыл бұрын
Anthony Reardon hvacr yep. On cold mornings they don't start up.
@eliseovalle2658
6 жыл бұрын
hi thank you
@persimonsen8792
5 жыл бұрын
Is it useable on reach-ins, with multiple txv's non ventilated (maybe ventilated to) and only one compressor. I've seen some of these and they never seem to run very good, which annoys me.
@carlosemmanuelgarciabrito791
3 жыл бұрын
My question is if that switch control the solenoid or you installed a tstat to de-energize it and make the system pump down ?
@eliseovalle2658
6 жыл бұрын
can you show me how do you ajust it pressure? i was paid attencion when you said that you goint to ajustet at 17 and them i got lost?
@UlisesPalacios
7 жыл бұрын
Good stuff bro. I know walk in freezers will use the low pressure cut out as a back up if the thermostat fails but I haven't worked on a walk in where the lps controls the temp. Merry Christmas.
@NorCal-refrigeration
7 жыл бұрын
Ulises Palacios merry Christmas 🎄
@drcolster
7 жыл бұрын
Hey Dave.. The scale showed 36 to 37 psi.. it cut in at 36.2.. Pretty close,Go Johnson
@MrPyk009
3 жыл бұрын
Hey bro . I have same unit . And my cooler is getting freeze few time . Please tell me what shouldi I set up ?
@raviyadav8743
3 жыл бұрын
Which app are you using in your mobile for PT chart.
@melusingcobo1735
3 жыл бұрын
Houzit man which app that you use for pressure switch settings i saw on that video Send me pls thanks
@hardcooling
7 жыл бұрын
I usually like all the old school stuff but that in particularly I hate they are usually never really accurate and in the winter naturally the adjustment would be off compared to summer so usually I would just tell the customer that I would change it to a thermostat with a solenoid
@NorCal-refrigeration
7 жыл бұрын
hardcooling I tried they did not want to spend the $. If it had food in there I would have done it. Just beer 🍻 in there.
@primetime758
7 жыл бұрын
here in toronto it's diferent if it was beer they would spend all types of money to make it the best . food .. meh as long as its working .
@apprenticephil649
6 жыл бұрын
prime time restaurants spend money on refrigeration in Toronto? Every customer I know wants a deal. Like below a livable wage kinda deal.
@AlaskanMonroe
3 жыл бұрын
What P-T CHART APP is that Dave? I’ll look through the other posts. Found it! It’s only on Apple that I can find. The RSD NOTES APP. I downloaded it for my iPad, but don’t have it for my Samsung Galaxy Note 8. Oh well,... On another note 📝,....Those pressure controls always confuse me. Any pointers to make understanding them better would be great. I like what you did, I just gotta watch the vid again to seal it in my brain! 😆. Thanks for posting great usable content,...as usual.
@craighardey3751
3 жыл бұрын
Why not set it with nitro before connecting it to the system?
@itz.meli.s3za
5 жыл бұрын
Is the line actually positive or negative
@user-mn2dk4yp2v
2 ай бұрын
🎉
@elcrazy8017
7 жыл бұрын
Thanks Nor Cal. Thats exactly what i have my line voltage stat set at 55 degrees. Does the condenser come on automatically on pressure? Or do i need to run control voltage to condenser unit contactor to energize the comp contactor? Do i need to add a jumper somewhere in the terminal strip in order to tell condenser im doing a pump down system?
@NorCal-refrigeration
7 жыл бұрын
Jose Alfaro your stat needs to energize a liquid line solenoid valve. The psi switch cycles the condensing unit.
@nates8183
7 жыл бұрын
good teaching dave, basicly if the unit used LLS,the pressure control used to turn on/off comp on 20 cut in and 5 cut out? thank you and Marry Cristmss
@NorCal-refrigeration
7 жыл бұрын
Nate S yes for 134a
@Colt-wr6wx
4 жыл бұрын
Half of the refrigeration at my job is controlled just by low pressure control. I normally set 15 and 35 give or take some controls aren't perfect
@NorCal-refrigeration
4 жыл бұрын
Yes sir. ❤️ it
@apprenticephil649
7 жыл бұрын
I did work in a restaurant with pressure controls controlling a prep table, walk in, and standard 4 door fridge. No t stat in sight. Have you ever found a leak coming from one of these controls Dave?
@NorCal-refrigeration
7 жыл бұрын
Apprentice Phil yes over time the bellows will leak, cap tubes will rub through.
@popsmccartney435
7 жыл бұрын
What app do you use for the TP chart?
@NorCal-refrigeration
7 жыл бұрын
Pops McCartney that one is on RSD app.
@kinggenius6660
7 жыл бұрын
bah humbug but thanks for making videos
@tito3971
7 жыл бұрын
DAVE HAVING AN ISSUE WITH A HOSHIZAKI KM SERIES ICE MACHINE 3 BEEPS REPLACED BOARD WATER VALVE AND CLEANED MACHINE AND FLOAT SWITCH STILL BEEPING AND NOTICED LINES FROSTING UP ANY SUGGESTIONS
@Bluecollarworkingman
6 жыл бұрын
tito Arroyo three beeps "freeze time"?
@muniznick
7 жыл бұрын
Biggy sez, Happy kwanzaa, nice video quality, what did you use.
@NorCal-refrigeration
7 жыл бұрын
muniznick iphone6s +
@elcrazy8017
7 жыл бұрын
What kind of PT Chart App you have on your phone?
@NorCal-refrigeration
7 жыл бұрын
Jose Alfaro it's on RSD app.
@elcrazy8017
7 жыл бұрын
Hey Nor Cal great video man. I currently work on HVAC systems only and i have a job im doing for a very good friend of mine. He has a wine cellar at his house being done and I installed a small ducted fan coil with a refrigeration Tecumseh condenser R404A.The fan coil installation instructions states unit to be set up as a pump down system and This video explained it all. I have a question regarding the cut in/cut out. Do you have an email i can message u?
@NorCal-refrigeration
7 жыл бұрын
Jose Alfaro on pump down for R404a set your cut in at 35 Psig. And have it cut out at 5 and you will be good. For wine have your Tstat set around 55-57
@mohamedmskini7335
2 жыл бұрын
Waw
@hvactechpr7872
7 жыл бұрын
anyone has that chart in pdf
@primetime758
5 жыл бұрын
why didn't you offer up installing a thermostat
@NorCal-refrigeration
5 жыл бұрын
It has a stay the psi switch is for pump down.
@primetime758
5 жыл бұрын
@@NorCal-refrigeration ooooooooo lol i thought you were doin old school temp control by the pressure control!!
@glennsepelak5113
5 жыл бұрын
there never close LMAO
@IFIXCASTLES
6 жыл бұрын
Not accurate at all!! Subject to outside factors..
Пікірлер: 116