I guess the operator wasn't used to a gas fryer...
@harrydickson4575
Жыл бұрын
👍👍👍
@inothome
Жыл бұрын
Never worked on a gas fryer, how do the vent / flue?
@davejohnsonnola1536
Жыл бұрын
Typically just an open stack at the back of the fryer, relying on the hood exhaust and make up air being balanced.
@inothome
Жыл бұрын
@@davejohnsonnola1536 Thanks, figured as much, but wasn't sure.
@deanmohamed7575
Жыл бұрын
i dont get it. It was not blocked up, but it was still popping?
@restaurantrepairs
Жыл бұрын
What you saw wasn’t popping beyond normal operation. I could monkey with the gas pressure to dial in the “proper” pilot and burner ratios but these locations bring their makeup air behind the fryers and they roll thru the bellies of them and blow out the pilots. This was one of the restaurants I manage, so I can get away with being like… “it’s good” I showed the staff me turning it on and off repeatedly without issue. 🤷♂️
@deanmohamed7575
Жыл бұрын
@@restaurantrepairs ahhh ok. got it. lol, Im taking this too serious 😁
@restaurantrepairs
Жыл бұрын
No your not. If that were a service call for a boom I would have had to dig much deeper. But given it’s one of my restaurants and my staff, we’re good with “it’s working” 😂
@davejohnsonnola1536
Жыл бұрын
I would advise breaking out the manometer just to make sure gas pressures not WAY out of whack.
@davejohnsonnola1536
Жыл бұрын
@@restaurantrepairs never seen makeup air behind the fyers, but my hotside point of reference is one property (horse race track / casino multiple concession stand/bars, three prep kitchens)