Just finished the wiring it was easy thanks for making this video
@fahimasghar6375
5 жыл бұрын
Very nice video Sir. Thanks
@ZOREDA100
3 жыл бұрын
Thanks 👍🏼really helpme
@aticafloorable
3 жыл бұрын
What parameters should I set for when the engine is running, the screen will only show me the revolutions. Thank you
@renosgarage7451
4 жыл бұрын
Very helpful thank you
@Crestone-saju
5 жыл бұрын
How do you change motor pole and motor speed "rpm"? Thank you
@user-zj3fx4yo8r
2 жыл бұрын
Hello. How to connect 3-wire( multe-speed ) control. What inverter settings need to be done? I can't figure it out. Thanks.
@martyscncgarage5275
6 жыл бұрын
Show demonstration with BRAKING resistor on GT series and fast decelleration to stop on 5hp motor. How fast can you stop without faulting the VFD
@traunicht1872
3 жыл бұрын
hello, someone has seen a similar video, or with DC braking
@briang7298
4 жыл бұрын
I have other inverters but cannot get this one to output power to motor even tho the inverter seems to be running. Please help.
@MarkThomas123
5 жыл бұрын
Where can I download the Manuals for the HY01D511B-T 110V In 1.5KW and GT-2R2G-2 220V In 2.2KW? Interested in both.. I think the programming has different numbers for parameters? HY01D511B-T does not come in a Vector version?
@huanyanginverter6516
5 жыл бұрын
Where can I download the Manuals for the HY01D511B-T 110V In 1.5KW and GT-2R2G-2 220V In 2.2KW? Interested in both.. I think the programming has different numbers for parameters? HY01D511B-T does not come in a Vector version?
@philjacobus5715
3 жыл бұрын
Just received myn1.5 kw water cooled dpindle. Inhavtbyo star the programming over so let’s see if I can do it. One thing noticed is a lot of vibration when the spindle is running. Should I be concerned?
@huanyanginverter6516
3 жыл бұрын
You take a video and send it to me eamil:xwdnzyp@163.com
@steveu235
3 жыл бұрын
Do all the gt series have the same program parameters and terminal for run jog stop etc.and also for using an external Potentiometer?
@huanyanginverter6516
3 жыл бұрын
Correct
@JeffLiebermann
6 жыл бұрын
The video says: "Note: Contactor or switch is forbidden to be installed between inverter's U,V,W terminals and motor". Why? Does the VFD require a permanent load? What happens if I run it without a motor or load attached?
@huanyanginverter6516
6 жыл бұрын
When the frequency converter is running, suddenly the motor is disconnected, which will lead to the damage of the frequency converter.
@josepastorjimenez
2 жыл бұрын
best regards friend. Excuse me, I have a Haunyang frequency variator, it would be GT, that has the keyboard locked and does not let me change anything. the control light with external keyboard flashes. Do you know how the variator is respected to reset everything to the factory?
@huanyanginverter6516
2 жыл бұрын
There is no way to replace the motherboard. . It can only be solved in the factory
@Elchapo62
Жыл бұрын
Can you make a diagram on jumpers setting using 485.
@kylerf150
3 ай бұрын
Hello, i have a gt series running a 7.5hp motor. I have a switch sends 220v to the vfd. Can I wire s1 and com together (connected all the time). That way when the vfd gets 220v it runs immediately after it boots up?
@huanyanginverter6516
3 ай бұрын
It can be done this way. Change parameters P1.16 = 1
@huanyanginverter6516
3 ай бұрын
KW, There is no need to change this parameter.
@MarshallDudley
Жыл бұрын
The video says to connect single phase power to R and T terminals. The Q and A on Amazon for this controller says to attach to R and S. Which is it?
@huanyanginverter6516
Жыл бұрын
Input voltage R, S R, T S, T It will be all right
@SanjivMaheshwari
4 жыл бұрын
Sir, can be use solar dc as input and get single and triple phase at the same time / different time to run two motors.
@huanyanginverter6516
4 жыл бұрын
DC input voltage 320V, single-phase motor can not be used.
@SanjivMaheshwari
4 жыл бұрын
ok thanks
@maxlevesque
10 ай бұрын
At 9.18m the video says "contact customer service" for break resistor when ordering... The problem is Amazon provides no way of contacting HuanYang, or any othe seller for that matter.
@huanyanginverter6516
10 ай бұрын
What problem are you encountering now?
@elroyjames8623
2 жыл бұрын
Hello I have a GT -7RSG~2 Running a 7.5hp 3 ph motor on a small block machine for vibrating the shaft and operating the pump However once I apply the load by activating the vibration the vfd keeps chipping...with error code oc1 and sometimes OH1
@huanyanginverter6516
2 жыл бұрын
VFD can only drive three-phase motors,
@elroyjames8623
2 жыл бұрын
@@huanyanginverter6516 I am using a three phase motor
@BackTheTooFuture
2 ай бұрын
Can you tell me what amps are needed for the 220V input on GT-7R5G-2?
@huanyanginverter6516
2 ай бұрын
50A
@huanyanginverter6516
2 ай бұрын
35A-50A
@marabunsewq4623
3 жыл бұрын
what current external start/stop button do i need for 5,5 hp motor. Is it ok with small current button?
@huanyanginverter6516
3 жыл бұрын
Yes, no need to consider current
@traunicht1872
3 жыл бұрын
@@huanyanginverter6516 how to brake the engine by injecting alternating current?
can I use a GT series VFD to control a 24 K rpm cnc spindle ?
@huanyanginverter6516
2 жыл бұрын
OK
@jjww9151
4 жыл бұрын
external potentiometer is shown connected to GND,AI2 and ACM but instructions say 10v,AI2 and ACM --- WHICH IS IT?
@huanyanginverter6516
4 жыл бұрын
ACM=GND
@Elchapo62
Жыл бұрын
Your manual very confusing, P2.01- I have a 2.2 KW motor, the setting range is 0.4-3000 for motor rated power, can you tell me what to enter . Also how do I change the frequency read out to RPM, I try the shift key doesn't work is the another key i have to enter?
@huanyanginverter6516
Жыл бұрын
P2.01 No change required Shift can display RPM
@Elchapo62
Жыл бұрын
@@huanyanginverter6516 thanks.
@aticafloorable
4 ай бұрын
sr the frequency in use is 60 HZ AND THE FREQUENCY OF MY MOTOR IS 50 HZ. THE PARAMETERS P0.03 60HZ, PO.O4 60HZ, P0.06 60HZ, AND FOR THE MOTOR P2.02 50HZ Is this correct? thank you
@huanyanginverter6516
4 ай бұрын
correct kzitem.info/news/bejne/w36Er5eKjoGZZZw
@stuartflys
4 жыл бұрын
Hi, what size potentiometer would you recommend?
@huanyanginverter6516
4 жыл бұрын
5K, OR 10K
@stuartflys
4 жыл бұрын
Huanyang inverter Is there a maximum length that the signal wires can be?
@AdamRhoads
3 ай бұрын
I have the 7.5kW VFD GT series. When i turn the power on to the VFD it displays 330V instead of the 230 I have at the input. I verified the input voltage to be correct with a multimeter. Is there a setting to change this?
@huanyanginverter6516
3 ай бұрын
SHIFT
@AdamRhoads
3 ай бұрын
I understand that the shift button cycles between options to display. When the LED for V is illuminated it reads 357. Should this be displaying 220 input voltage instead?
@huanyanginverter6516
2 ай бұрын
@@AdamRhoads Yes, the display shows DC voltage.
@huanyanginverter6516
2 ай бұрын
@@AdamRhoads yes
@huanyanginverter6516
2 ай бұрын
@@AdamRhoads The displayed voltage is a bit high
@ruzannasahakyan
4 ай бұрын
Hello. Please tell me how to connect and configure the NC Studio program with HY HUANYANG GT-7R5G-2
@huanyanginverter6516
4 ай бұрын
This scope is too broad, you need to go into specific details. What functions are achieved. Draw a sketch for me.
@Dragon90815a
3 жыл бұрын
Do you have a manual for all of these codes and functions?
@huanyanginverter6516
3 жыл бұрын
yes You can contact with me email:xwdnzyp@163.com
@elshantagiyev
3 жыл бұрын
Hello everyone, please help me. I have connected VFD GT 2.2kw between NOVUSUN NVEM v2 + mach 3 controller. But I am having a problem I cannot adjust the spindle speed for match3. When enabled through match 3, the speed increases to the maximum. Help how to connect correctly
@huanyanginverter6516
3 жыл бұрын
Your question cannot be answered in a few sentences. . . You have to provide drawings of MACH3. . You need to set the functions of these terminals S1, S2, S3, and S4.
@jonoanderson8025
Жыл бұрын
I have huanyang gt 4kw 220v 1ph in 3ph out running 230v 3ph induction motor 50hz 2.2kw 3hp 2800rpm 8.7A. I set motor parameters p2.01,02,03,04,05 as motor name plate. And settings hz p0.03=50hz p0.04=50hz p0.05=0hz p0.06=50hz p0.07=1 then auto run auto tune no problem. Then motor works in v/f mode but when switch to vector control motor makes noise and wont spin. I want to run in vector mode for low speed torque and control speed through control pad potentiometer can you help me please.
@huanyanginverter6516
Жыл бұрын
Restore the parameters and directly control the vector
@huanyanginverter6516
Жыл бұрын
P0.17 = 1 P0.07 = 1 P0.00 = 1
@Elchapo62
Жыл бұрын
Can you do a video on 485 communication with GT series VFD.
@huanyanginverter6516
Жыл бұрын
kzitem.info/news/bejne/mKmM0X1ji5ZknH4
@aticafloorable
3 жыл бұрын
Mr my motor is 3 KW. 4 HP. 11.8 / 6.8 A. 1400 RPM. 50 HZ. 220/380 V. IT IS FROM A CEMENT POLISHING MACHINE THAT I MUST SET PARAMETERS. THANKS. THE MODEL IS THE SAME FROM THE VIDEO
@Phantom-mk4kp
6 жыл бұрын
i Hi I have a 220v 7.5 KW GT version where can i download a manual Thanks
@huanyanginverter6516
6 жыл бұрын
could you send me your email?I will send it to you
@Phantom-mk4kp
6 жыл бұрын
karl.harvest@gmail.com Many thanks
@steveu235
3 жыл бұрын
I Have 2 jog buttons one reverse one forward the default frequency is 5 where can i Change this.Thanks
@huanyanginverter6516
3 жыл бұрын
You change the forward and reverse parameters in the, video.
@steveu235
3 жыл бұрын
@@huanyanginverter6516 I found it in the book thanks
@Hackjob-Extraordinaire
2 жыл бұрын
hello, i cant get my motor to run!! inverter model gt 5r5g 2 with 220v 3 phase motor 5hp 1725rpm
@huanyanginverter6516
2 жыл бұрын
motor access uvw just fine
@Hackjob-Extraordinaire
2 жыл бұрын
@@huanyanginverter6516 what?
@Hackjob-Extraordinaire
2 жыл бұрын
@@huanyanginverter6516 its hooked up properly and doesnt run
@huanyanginverter6516
2 жыл бұрын
@@Hackjob-Extraordinaire Shoot a video and send it to me
@Hackjob-Extraordinaire
2 жыл бұрын
@@huanyanginverter6516 where do i send it?
@aticafloorable
2 жыл бұрын
could you please make a video illustrating the same thing but with a 5.5 kW 7.5 HP 220 V
@huanyanginverter6516
2 жыл бұрын
What problem are you having?
@aticafloorable
2 жыл бұрын
@@huanyanginverter6516 Mr. I want to buy. the model 5.5 kW 7.5 HP 220 V AC 25 A I want to know if the configuration and the terminals are the same as the model 4 kw 5 Hp. I bought a 4 Kw and your video helped me to program lpsandos remotely now I want to buy a 5 Kw and I want to know if your video will also help me with this. Thank you
@steveu235
3 жыл бұрын
I have flashing red lights what causes this I see nothing in the book about the flashing leds
@steveu235
3 жыл бұрын
Found the problem the com and the 10v of potentiometer have to be connected at the right place cant be interchanged
@huanyanginverter6516
3 жыл бұрын
Excuse me, which specification do you buy?
@huanyanginverter6516
3 жыл бұрын
Which country
@pomonabill220
Жыл бұрын
Nice video.. couldn't stand the tinkly music though!!!!!!
@khurramshaikh4347
3 жыл бұрын
Vfd setting save not saved please help
@huanyanginverter6516
3 жыл бұрын
Can't understand what you mean, you sent it to me in a video. Email:xwdnzyp@163.com
@cache3738
4 жыл бұрын
Just like you said, i leave a message here. Here is my problem with the inverter kzitem.info/news/bejne/p395mWiCsZeigoI The UP button is not working.
@huanyanginverter6516
4 жыл бұрын
Great. I can finally get in touch with you.
@huanyanginverter6516
4 жыл бұрын
Can you tell me the email? I'll send you the video
@jeffreyehrens4843
4 жыл бұрын
How the heck do you simply change from 50HZ to 60 HZ. This is so basic and info unobtainable Huge PITA for something so basic . Read the manual 1 0x and useless for me Frustrating