it shoe run when we start when we enter in fn002 it show n0-0p. set in fn010 and fn200 .. . but problem is still
@yavandala7374
2 жыл бұрын
How to set from "bb" to "run"?
@rickstard73
2 жыл бұрын
Hi, I have 4 drives on a CNC router with Yaskawa SGDV servo packs, they are all working fine, but when I connect 1 to SigmaWin+ 7 it connects fine by USB, but I cannot connect the other 3, is there a setting on the drives I need to set to be able to connect to them?
@aemechatronics1806
2 жыл бұрын
USB CABLE YOU USE MUST BE SHIELDED AND FERRITED. AS THE CONNECTOR IS OF USB TYPE MINI DUST IN THE DRIVE CONNECTOR AND POWER GROUDING CAUSES SUCH PROBLEM. THERE IS NO PARAMETER SETTINGS REQUIRED!
@miminsoo12
Жыл бұрын
hello bro, I have the sgdv-200A01A and it seems to show the 030 error code do you know how to fix it? cuz i couldn't find the way to fix it?
@aemechatronics1806
Жыл бұрын
Power module is faulty. It is called main circuit detector error. Which is major category of fault. Try to send to service center for repair or replace new.
@MuhammadAhsan-ig9tz
4 жыл бұрын
may be i am not set in proper way
@MuhammadAhsan-ig9tz
4 жыл бұрын
it is necessary servo motor and servo amplifier model number same.
@aemechatronics1806
3 жыл бұрын
Means I can't understand clearly
@agungbagus5352
Жыл бұрын
Hello. When try jog mode, appear no_op. What the problem?
@aemechatronics1806
Жыл бұрын
Check main circuit input power
@tigranshahverdyan968
Жыл бұрын
Привет брат У меня возникла проблема с этот пакетом у меня от П Л С не идёт сигнал на сервопакет То есть он не читает ничего не сделает и пишет только p o t и не работает сможете мне помочь пожалуйста
@mdmajedurrahaman9967
2 жыл бұрын
Why the main motor servo came
@aemechatronics1806
2 жыл бұрын
No clear?
@MuhammadAhsan-ig9tz
4 жыл бұрын
please reply
@Lecky215
4 жыл бұрын
Bro i have sgd7s-200a00b202 servopack200/yaskawa...how to increase the speed of this drive?....and what parameter no.should i udjust?rply pls
@aemechatronics1806
4 жыл бұрын
Hi what does the display show? bb or Run? What is the value in Pn000?
@aemechatronics1806
4 жыл бұрын
Hi what does the display show? bb or Run? What is the value in Pn000?
@mdaktaruzzaman9380
4 жыл бұрын
@@aemechatronics1806 00
@aemechatronics1806
4 жыл бұрын
What is the value parameter no Pn000, pn300, opn 20e,pn210, pn212?
@jogendrasinghranawat6034
2 жыл бұрын
@@aemechatronics1806 hi sir, I m facing an error which is 810 how can this be resolved??
@MuhammadAhsan-ig9tz
4 жыл бұрын
how we remove n0-0p i have try more time time but i fail. .
@aemechatronics1806
4 жыл бұрын
What does the display show? bb or Run? May be when u are in Run mode some functions are not allowed
@aemechatronics1806
4 жыл бұрын
Check anf reply
@ssobolrac8012
3 жыл бұрын
Bro how about this model sgdv-2r1f01a
@aemechatronics1806
3 жыл бұрын
What you need about this model?
@ssobolrac8012
3 жыл бұрын
I got stuck on e_not e_pot blinking, what do I need to do?
@MuhammadAhsan-ig9tz
4 жыл бұрын
hello
@aemechatronics1806
4 жыл бұрын
Drive display should show BB and charge indication lamp should be on then if u access fn002 u will be able run. U can send me a video on WhatsApp at +919930044314
@MuhammadAhsan-ig9tz
4 жыл бұрын
sgdv model number
@tigranshahverdyan968
Жыл бұрын
hi can you help me
@aemechatronics1806
Жыл бұрын
Yes pls
@yavandala7374
2 жыл бұрын
How to set from"bb" to "run"?
@aemechatronics1806
2 жыл бұрын
Generally bb means servo ready and awaiting for run command at Cn1 pin no.40. You can you 24vdc to cn1 pin no 40. And 0vdc Cn1 pin no47, this will make servo to change from bb to Run
@aemechatronics1806
2 жыл бұрын
Or other option is make PN50A=2100 ==>>2170 Or PN50A=8100==>>8170 7 means it forces servo to run mode
Пікірлер: 37