Discover one of the most common causes that cause this ERROR E2 so mentioned and that brings many users of pellet cookers, NEMMAX, DOKII, Extraflame, Albin Trotter, IFLAME and many others that are equipped with CLBIO controllers.
By manual they describe 4 possible causes and all of them are valid, but really in many cases this ERROR E2 is unknown that one of the most common causes is the deficient load of pellets in the ignition cycle of the cooker.
Yes friends, really the community of BIOMASS FOR ALL works, and the comments that you leave us here under each video we publish and the amount of messages you send us through our website, helps us to detect and correct in many aspects problems that have easy solutions, and many of them without spending a single Euro in spare parts or costly repairs.
That is why we continue to publish and spread the message of BIOMASS FOR EVERYONE, as a change and we are proud that this family continues to grow, and among all promote the knowledge and operation of pellet cookers and the most typical parameter errors.
It is important to know each of the MISTAKES in pellet cookers and what are their possible causes.
That is why from BIOMASS FOR EVERYONE we always advise you to read the contents of the pellet cooker manuals, to know the correct operation of a pellet cooker, possible errors and how to solve them.
If for any reason you do not have the original manual, we have great news for all of you and that is that from January 2023, we are launching a new download section on our website.
There you can download a huge amount of user manuals for many brands of pellet cookers and we continue to add week after week.
In addition to downloading pellet cooker parameters of the most famous controllers and used in the industry of domestic and industrial pellet cookers.
But back to the subject of ERROR E2 and pellet underloading, it is important that you watch this video and you can solve yourselves this error that brings so many people upside down with their pellet cookers.
Simply enter the user menu of your cooker and go to parameter 7 and check the current values.
Once you have checked this you should apply the correction according to the height of the orifice of your pellet burner and always be at least 1 centimetre above this.
The process can be done gradually and in several ignition cycles of the cooker, you will get a correct calibration and without errors in the ignition of pellet cookers.
ERROR MESSAGES:
Error E1
This error is due to the flue gas temperature being below 40-45°, the probable causes of which are as follows:
1. Not enough pellet.
2. The worm motor is faulty and does not feed the cooker.
Error E2
This error is due to a misfire at start-up. Probable causes may be:
1. The burner is dirty or has hard residue on it.
2. The ashtray has not been correctly installed.
3. The flue gas temperature sensor on the combustion fan is faulty.
4. The ignition resistor is faulty.
Error E3
Means that there has been a sudden movement of the cooker during operation or the cooker has tilted. This error code is mainly programmed for earthquake zones.
Error E4
Problems with the temperature sensor.
Means that the high temperature sensor is faulty.
The temperature is so high that the cooker does not work properly.
Error E5
It means that there are some problems with vacuum switch. Such as the door has not closed properly.
The combustion fan speed cannot accelerate.
There is some leakage around the cooker or the flue pipe is blocked.
Error E6
It means that the high temperature sensor under the hopper has some problem, such as:
1 . The switch is broken,
2. The temperature is too high and causes the cooker to shut down.
Error E7
During operation the cooker has stopped due to a power failure.
Don't miss this interesting video which is claimed by many people and of which we will make a series.
Don't miss the next video next week...
We will talk about "The secrets of easy access".
If you like the information and videos with your simple subscription and alert in the notifications you help us a lot to continue creating quality content.
SUBSCRIBE: / biomasapara. .
www.biomasaparatodos.com
We hope to see you often on the channel and count on your comments to stay in touch and generate great feedback for the entire community.
We believe in change, we are committed to the environment, we make biomass a way of life.
Негізгі бет Ғылым және технология ERROR E2 in CLBIO controllers, discover the most common cause and how to solve it. Pellet load.
Пікірлер: 15