Setup for Thermocouple Input on a 1ET05225 (PM6C1EC-AAAAABA) temperature controller.
To enter set up menu push and hold the up and down arrow keys for approximately 3 seconds, LoC is displayed on the lower display.
Once there, push the green advance key once to SEn displayed on the lower display, then use the down key to select the sensor type which is on the upper display.
Set to tC -- Thermocouple.
Push the green advance key once, L in is displayed on the lower display, then use the down key to select the thermocouple type which is on the upper display.
J -- Type J Thermocouple, H -- Type K Thermocouple, n -- Type N Thermocouple,
S -- Type S Thermocouple, t -- Type T Thermocouple.
Push the green advance key twice until C_F is displayed on the lower display, then use the down key to select the range which is on the upper display to select C which is °C.
Push the green advance key once, r.Lo is displayed on the lower display, then use the down key to select the low range of the set point which is on the upper display.
Usually this is 0 °C
Push the green advance key once, r.hi is displayed on the lower display, then use the down key to select the high range of the set point which is on the upper display.
Usually this is a extra safety measure for you to set the highest temperature you would want the operator's to use in °C. You may however prefer to set this higher so as not to limit use of temperature controller for higher temperatures later on.
You can return to the default display by pushing the infinity key.
For more information visit: www.cynebar.com.au/