I was trying to use one of these inverter motor speed controllers to run a flat pancake motor mounted on the back of the drum on a Maytag (similar to Samsung) washing machine but without success. The controller doesn't seem to provide enough starting current to make the motor run so all it does is vibrate back and forth a bit but doesn't turn. An externally mounted square motor that runs the drum with a belt runs OK using the controller however.
@jasonwong1303
5 жыл бұрын
adjust the acceleration profile to start slow and ramp up.
@CenturyHearingAids
5 жыл бұрын
I dont get it; can you use the 110V to run a single phase motor?
@huanyanginverter6516
5 жыл бұрын
Single phase motor cannot run
@Dragon90815a
3 жыл бұрын
Needs better function discriptions and parameters for each.
@Phantom-mk4kp
6 жыл бұрын
Do you have your own web site
@Diego-lx4ui
4 жыл бұрын
I got one displaying the error "DL" when it is started. Does anyone can help me about it? thanks
@huanyanginverter6516
4 жыл бұрын
You can disconnect the motor test
@rok1475
3 жыл бұрын
Will a 5.5kW inverter drive 7.5HP motor off single phase 230V ? I found some information indicating that I have to buy an inverter that is double the rates power of the motor when input is a single phase. Is that true with your inverters?
@huanyanginverter6516
3 жыл бұрын
Single-phase 230V, large current. Voltage X current = power. It adopts single-phase electricity to drive 5.5KW motor, and the current is very large.
@rok1475
3 жыл бұрын
@@huanyanginverter6516 yes, that is my concern- can rectifier in the inverter handle the higher current from single phase ? If it was connected to 3 phase power then each phase would carry about 8A @230V driving 5.5kW load. But with single phase each input line will carry about 12A. Can the 5.5kW inverter handle that?
@huanyanginverter6516
3 жыл бұрын
@@rok1475 What you said is correct. The rectifier part will withstand higher currents, it cannot be done like this, the power must be reduced
@rok1475
3 жыл бұрын
@@huanyanginverter6516 so can I use Huanyang 5.5kW inverter connected to single phase 230V AC to drive 7,5HP motor or should I get 10kW inverter?
@huanyanginverter6516
3 жыл бұрын
You should buy a more powerful inverter, 7.5KW Then the load is lighter when the motor is in use
@larrywmedford6587
5 жыл бұрын
I would prefer to have the video without the music. I clicked on this video to learn about the VFD not listen to music. If I wanted music, I would go somewhere else.
@huanyanginverter6516
5 жыл бұрын
Your friend is very right. The video will no longer be inserted in the future.
@gustavozuniga6463
3 жыл бұрын
Deben de hacer un vídeo en español no MAMEN
@user-mr1sm4gx3n
4 жыл бұрын
какие паразиты ставят дизы ????=(((((((
@msdesignru
6 жыл бұрын
If you need more views and more buyers just let us know, we are able to help you with it...
@huanyanginverter6516
6 жыл бұрын
Sorry, I didn't reply in time, because China is now on New Year's holiday.Do you want to be my agent?
@msdesignru
6 жыл бұрын
Yes, I know that it is New Year Holidays in China now. We can promote your products by sharing it with our internet audience. It works pretty good. We already reviewed one item from your store, you can check it on our channel...
@steveu235
5 жыл бұрын
Mine lasted about 20 minutes changed a parameter to within the allowed specs and went pouf these inverters are garbage
@huanyanginverter6516
5 жыл бұрын
The frequency of the inverter is inconsistent with the motor, which will cause the motor to heat up and eventually burn out. It is very important to change the frequency of the inverter.
@huanyanginverter6516
5 жыл бұрын
The frequency of the inverter can be changed@@FluxApexEng